High-speed spectral-domain optical coherence tomography at 1.3 μm wavelength

被引:372
作者
Yun, SH
Tearney, GJ
Bouma, BE
Park, BH
de Boer, JF
机构
[1] Harvard Univ, Sch Med, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Wellman Ctr Photomed, Boston, MA 02114 USA
来源
OPTICS EXPRESS | 2003年 / 11卷 / 26期
关键词
D O I
10.1364/OE.11.003598
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate a high-speed spectral domain optical coherence tomography (SD-OCT) system capable of acquiring individual axial scans in 24.4 mus at a rate of 19,000 axial scans per second, using an InGaAs line scan camera and broadband light source centered at 1.31 mum. Sensitivity of >105 dB over a 2-mm depth range was obtained with a free-space axial resolution of 12-14 mum, in agreement with our signal-to-noise ratio predictions. Images of human tissue obtained in vivo with SD-OCT show similar penetration depths to those obtained with state-of-the-art time domain OCT despite the ten-fold higher image acquisition speed. These results demonstrate the potential of 1.3 mum SD-OCT for high-speed and high-sensitivity imaging in patients. (C) 2003 Optical Society of America.
引用
收藏
页码:3598 / 3604
页数:7
相关论文
共 18 条
[1]  
Andretzky P, 1998, P SOC PHOTO-OPT INS, V3567, P78
[2]   Clinical imaging with optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ .
ACADEMIC RADIOLOGY, 2002, 9 (08) :942-953
[3]   Optical coherence tomography using a frequency-tunable optical source [J].
Chinn, SR ;
Swanson, EA ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (05) :340-342
[4]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[5]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[6]   Spectral resolution and sampling issues in Fourier-transform spectral interferometry [J].
Dorrer, C ;
Belabas, N ;
Likforman, JP ;
Joffre, M .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2000, 17 (10) :1795-1802
[7]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[8]   Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser [J].
Golubovic, B ;
Bouma, BE ;
Tearney, GJ ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (22) :1704-1706
[9]  
Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
[10]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894