Acoustic quantification of ATP using a quartz crystal microbalance with dissipation

被引:25
作者
Cengiz Oezalp, Veli [1 ]
机构
[1] Univ Basque Country, San Sebastian 20018, Spain
关键词
DNA APTAMER; ADENOSINE; AFFINITY; NANOPARTICLES; RECOGNITION; BIOSENSOR; PROTEIN; PROBE; RNA; PH;
D O I
10.1039/c1an15762k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A quartz crystal microbalance with a dissipation monitoring (QCM-D) sensor was developed for highly sensitive and specific detection of adenosine-5'-triphosphate (ATP) by using an aptamer. The binding of ATP molecules on the aptamer films could be calculated as accurate mass changes using multiple frequency and dissipation measurements. The detection is achieved by calculating the mass changes from conformational rearrangements of the sensor surface upon interaction with the target. The sensor was demonstrated to respond to changes in ATP concentrations in real time suitable for continuous monitoring applications. This sensor showed excellent selectivity toward ATP compared with other chemically similar nucleotide GTP. The feasibility of the sensor was demonstrated by analyzing ATP concentrations in cell culture media with serum. The maximum frequency change was about 2 Hz after injection of 500 mu M ATP. The affinity constant of the aptamer was determined to be 49 +/- 7.59 mu M. The proposed sensor can extend the application of the QCM-D system in medical diagnosis, and could be adopted for the detection of other small molecules with the use of specific aptamers.
引用
收藏
页码:5046 / 5050
页数:5
相关论文
共 38 条
[1]   Adenosine triphosphate - Established and potential clinical applications [J].
Agteresch, HJ ;
Dagnelie, PC ;
van den Berg, JWO ;
Wilson, JHP .
DRUGS, 1999, 58 (02) :211-232
[2]   Comparative analysis of QCM and SPR techniques for the optimization of immobilization sequences [J].
Ansorena, P. ;
Zuzuarregui, A. ;
Perez-Lorenzo, E. ;
Mujika, M. ;
Arana, S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02) :667-672
[3]   Real-time aptamer quantum dot fluorescent flow sensor [J].
Bogomolova, Anastasia ;
Aldissi, Matt .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (10) :4099-4103
[4]   Aptamer-Gated Nanoparticles for Smart Drug Delivery [J].
Cengiz Ozalp, Veli ;
Eyidogan, Fusun ;
Oktem, Huseyin Avni .
PHARMACEUTICALS, 2011, 4 (08) :1137-1157
[5]   Amplified QCM-D biosensor for protein based on aptamer-functionalized gold nanoparticles [J].
Chen, Qiang ;
Tang, Wei ;
Wang, Dingzhong ;
Wu, Xiaojie ;
Li, Na ;
Liu, Feng .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :575-579
[6]   Colorimetric determination of urinary adenosine using aptamer-modified gold nanoparticles [J].
Chen, Shih-Ju ;
Huang, Yu-Fen ;
Huang, Chih-Ching ;
Lee, Kun-Hong ;
Lin, Zong-Hong ;
Chang, Huan-Tsung .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) :1749-1753
[7]  
Chiu TC, 2007, RECENT PAT NANOTECH, V1, P99
[8]   Aptamer-Functionalized Nano-Biosensors [J].
Chiu, Tai-Chia ;
Huang, Chih-Ching .
SENSORS, 2009, 9 (12) :10356-10388
[9]   THE USE OF ATP BIOLUMINESCENCE AS A MEASURE OF CELL-PROLIFERATION AND CYTOTOXICITY [J].
CROUCH, SPM ;
KOZLOWSKI, R ;
SLATER, KJ ;
FLETCHER, J .
JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 160 (01) :81-88
[10]   Retention and separation of adenosine and analogues by affinity chromatography with an aptamer stationary phase [J].
Deng, Q ;
German, I ;
Buchanan, D ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 2001, 73 (22) :5415-5421