Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model

被引:246
作者
Bae, KT [1 ]
Heiken, JP [1 ]
Brink, JA [1 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, Sch Med, St Louis, MO 63110 USA
关键词
aorta; CT; computed tomography (CT); contrast enhancement; helical; heart failure; liver;
D O I
10.1148/radiology.207.3.9609887
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To investigate how reduction in cardiac output affects the magnitude and timing of aortic and hepatic contrast medium enhancement during abdominal computed tomography (CT). MATERIALS AND METHODS: Eight 20-30-kg pigs underwent CT before and after pharmacological reduction of cardiac output (measured by means of thermodilution). Each CT study consisted of 53 dynamic images acquired every 5 seconds at a fixed level through the midliver after intravenous injection of contrast medium (concentration, 282 mg of iodine per milliliter; dose, 2 mL per kilogram of body weight; injection rate, 2 mL/sec). Curves of contrast medium enhancement versus time were measured. Changes in the magnitude and timing of aortic and hepatic enhancement were compared with the reduction in cardiac output. RESULTS: With the reduction in cardiac output, the time from the injection start to the arrival of the contrast medium bolus in the aorta (P < .01) and the times from injection completion to peak aortic (P < .01) and peak hepatic (P < .01) enhancement increased. As cardiac output decreased, peak aortic enhancement increased proportionally (P < .01). Peak hepatic enhancement increased only slightly and correlated weakly with the decrease in cardiac output (P = .07). CONCLUSION: As cardiac output decreases, the times to the arrival of the contrast medium bolus in the aorta and to peak aortic and hepatic enhancement increase. Reduction in cardiac output results in a substantial increase in peak aortic enhancement but not in peak hepatic enhancement.
引用
收藏
页码:657 / 662
页数:6
相关论文
共 7 条
[1]
Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[2]
DYNAMIC INCREMENTAL CT - EFFECT OF VOLUME AND CONCENTRATION OF CONTRAST MATERIAL AND PATIENT WEIGHT ON HEPATIC ENHANCEMENT [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
CROWE, TM ;
GAINES, MV .
RADIOLOGY, 1995, 195 (02) :353-357
[3]
HEMODYNAMIC-EFFECTS OF DIFFERENT CALCIUM-ANTAGONISTS IN THE HEART-LUNG PREPARATION OF THE GUINEA-PIG [J].
JAP, TJW ;
BODDEKE, HWGM ;
VANDEHAAR, V ;
VANZWIETEN, PA .
PHARMACOLOGY, 1988, 36 (06) :371-379
[4]
DYNAMIC CONTRAST ENHANCEMENT OF THE UPPER ABDOMEN - EFFECT OF CONTRAST-MEDIUM AND BODY-WEIGHT [J].
KORMANO, M ;
PARTANEN, K ;
SOIMAKALLIO, S ;
KIVIMAKI, T .
INVESTIGATIVE RADIOLOGY, 1983, 18 (04) :364-367
[5]
OPTIMAL CONTRAST ENHANCEMENT OF THE LIVER USING HELICAL (SPIRAL) CT - VALUE OF SMARTPREP [J].
SILVERMAN, PM ;
BROWN, B ;
WRAY, H ;
FOX, SH ;
COOPER, C ;
ROBERTS, S ;
ZEMAN, RK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1169-1171
[6]
POSTTRAUMATIC SHOCK IN CHILDREN - CT FINDINGS ASSOCIATED WITH HEMODYNAMIC INSTABILITY [J].
SIVIT, CJ ;
TAYLOR, GA ;
BULAS, DI ;
KUSHNER, DC ;
POTTER, BM ;
EICHELBERGER, MR .
RADIOLOGY, 1992, 182 (03) :723-726
[7]
HYPOVOLEMIC SHOCK IN CHILDREN - ABDOMINAL CT MANIFESTATIONS [J].
TAYLOR, GA ;
FALLAT, ME ;
EICHELBERGER, MR .
RADIOLOGY, 1987, 164 (02) :479-481