Compound-Specific Chlorine Isotope Analysis: A Comparison of Gas Chromatography/Isotope Ratio Mass Spectrometry and Gas Chromatography/Quadrupole Mass Spectrometry Methods in an Interlaboratory Study

被引:87
作者
Bernstein, Anat [1 ]
Shouakar-Stash, Orfan [2 ]
Ebert, Karin [3 ]
Laskov, Christine [3 ]
Hunkeler, Daniel [4 ]
Jeannottat, Simon [4 ]
Sakaguchi-Soeder, Kaori [5 ]
Laaks, Jens [6 ]
Jochmann, Maik A. [6 ]
Cretnik, Stefan [1 ]
Jager, Johannes [5 ]
Haderlein, Stefan B. [3 ]
Schmidt, Torsten C. [6 ]
Aravena, Ramon [2 ]
Elsner, Martin [1 ]
机构
[1] German Res Ctr Environm Hlth GmbH, Helmholtz Zentrum Munchen, D-85764 Neuherberg, Germany
[2] Univ Waterloo, Dept Earth & Environm Sci, W Waterloo, ON, Canada
[3] Univ Tubingen, Ctr Appl Geosci ZAG, D-72076 Tubingen, Germany
[4] Univ Neuchatel, Ctr Hydrogeol & Geotherm CHYN, CH-2009 Neuchatel, Switzerland
[5] Tech Univ Darmstadt, Inst WAR, Fachgebiet Abfalltech, D-64287 Darmstadt, Germany
[6] Univ Duisburg Essen, Instrumental Analyt Chem, D-45141 Essen, Germany
基金
加拿大自然科学与工程研究理事会; 瑞士国家科学基金会;
关键词
ORGANIC CONTAMINANTS; REDUCTIVE DECHLORINATION; STABLE CHLORINE; CARBON; FRACTIONATION; TRANSFORMATION; SOLVENTS; HYDROGEN; MTBE; BIODEGRADATION;
D O I
10.1021/ac200516c
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
Chlorine isotope analysis of chlorinated hydrocarbons like trichloroethylene (TCE) is of emerging demand because these species are important environmental pollutants. Continuous flow analysis of noncombusted TCE molecules, either by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) or by GC/quadrupole mass spectrometry (GC/qMS), was recently brought forward as innovative analytical solution. Despite early implementations, a benchmark for routine applications has been missing. This study systematically compared the performance of GC/qMS versus GC/IRMS in six laboratories involving eight different instruments (GC/IRMS, Isoprime and Thermo MAT-253; GC/qMS, Agilent 5973N, two Agilent 5975C, two Thermo DSQII, and one Thermo DSQI). Calibrations of Cl-37/Cl-35 instrument data against the international SMOC scale (Standard Mean Ocean Chloride) deviated between instruments and over time. Therefore, at least two calibration standards are required to obtain true differences between samples. Amount dependency of delta Cl-37 was pronounced for some instruments, but could be eliminated by corrections, or by adjusting amplitudes of standards and samples. Precision decreased in the order GC/IRMS (1 sigma approximate to 0.1 parts per thousand), to GC/qMS (1 sigma approximate to 0.2-0.5 parts per thousand for Agilent GC/qMS and 1 sigma approximate to 0.2-0.9 parts per thousand for Thermo GC/qMS). Nonetheless, delta Cl-37 values between laboratories showed good agreement when the same external standards were used. These results lend confidence to the methods and may serve as a benchmark for future applications.
引用
收藏
页码:7624 / 7634
页数:11
相关论文
共 40 条
[1]
Carbon and Chlorine Isotope Fractionation during Aerobic Oxidation and Reductive Dechlorination of Vinyl Chloride and cis-1,2-Dichloroethene [J].
Abe, Y. ;
Aravena, R. ;
Zopfi, J. ;
Shouakar-Stash, O. ;
Cox, E. ;
Roberts, J. D. ;
Hunkeler, D. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (01) :101-107
[2]
Direct Compound-Specific Stable Chlorine Isotope Analysis of Organic Compounds with Quadrupole GC/MS Using Standard Isotope Bracketing [J].
Aeppli, Christoph ;
Holmstrand, Henry ;
Andersson, Per ;
Gustafsson, Orjan .
ANALYTICAL CHEMISTRY, 2010, 82 (01) :420-426
[3]
[Anonymous], HDB STABLE ISOTOPE A
[4]
Isotopic characterization of chlorinated solvents-laboratory and field results [J].
Beneteau, KM ;
Aravena, R ;
Frape, SK .
ORGANIC GEOCHEMISTRY, 1999, 30 (8A) :739-753
[5]
An interlaboratory study to test instrument performance of hydrogen dual-inlet isotope-ratio mass spectrometers [J].
Brand, WA ;
Coplen, TB .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (04) :358-362
[6]
Stable chlorine and carbon isotopic compositions of selected semi-volatile organochlorine compounds [J].
Drenzek, NJ ;
Tarr, CH ;
Eglinton, TI ;
Heraty, LJ ;
Sturchio, NC ;
Shiner, VJ ;
Reddy, CM .
ORGANIC GEOCHEMISTRY, 2002, 33 (04) :437-444
[7]
Evaluating chlorine isotope effects from isotope ratios and mass spectra of polychlorinated molecules [J].
Elsner, Martin ;
Hunkeler, Daniel .
ANALYTICAL CHEMISTRY, 2008, 80 (12) :4731-4740
[8]
Insight into methyl tert-butyl ether (MTBE) stable isotope Fractionation from abiotic reference experiments [J].
Elsner, Martin ;
Mckelvie, Jennifer ;
Couloume, Georges Lacrampe ;
Lollar, Barbara Sherwood .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (16) :5693-5700
[9]
Stable isotope fractionation to investigate natural transformation mechanisms of organic contaminants: principles, prospects and limitations [J].
Elsner, Martin .
JOURNAL OF ENVIRONMENTAL MONITORING, 2010, 12 (11) :2005-2031
[10]
Assessing Transformation Processes of Organic Compounds Using Stable Isotope Fractionation [J].
Hofstetter, Thomas B. ;
Schwarzenbach, Rene P. ;
Bernasconi, Stefano M. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (21) :7737-7743