Electrospray ionization with ambient pressure ion mobility separation and mass analysis by orthogonal time-of-flight mass spectrometry

被引:65
作者
Steiner, WE
Clowers, BH
Fuhrer, K
Gonin, M
Matz, LM
Siems, WF
Schultz, AJ
Hill, HH [1 ]
机构
[1] Washington State Univ, Dept Chem, Pullman, WA 99164 USA
[2] Ionwerks Inc, Houston, TX 77005 USA
关键词
D O I
10.1002/rcm.495
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rapid screening and identification of drug and other mixtures are possible using a novel ambient pressure high-resolution ion mobility (APIMS) orthogonal reflector time-of-flight mass spectrometer (TOFMS). Departing ions from the APIMS drift tube traversed a pressure interface between the APIMS and TOFMS where they were subjected to numerous gas collisions that could produce selective fragmentation. By increasing the accelerating field in the pressure interface region, the ions generated using water-cooled electrospray ionization (ESI) underwent collision-induced dissociation (CID). Mixtures of ESI ions were separated by APIMS based on their respective size-to-charge (s/z) ratios while CID and analysis of mass-to-charge (m/z) ratios occurred in the pressure interface and TOFMS. Product ions that were formed in this pressure interface region could be readily assigned to precursor ions by matching the mobility drift times. This process was demonstrated by the examination of a mixture of amphetamines and the resulting fragmentation patterns of the mobility-separated precursor ion species [M + H](+). Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:2221 / 2226
页数:6
相关论文
共 20 条
[1]  
ASBURY RG, 2000, MICROCOLUMN SEPARATI, V12, P391
[2]   Absolute values of the electron mobility in hydrogen [J].
Bradbury, NE ;
Nielsen, RA .
PHYSICAL REVIEW, 1936, 49 (05) :0388-0393
[3]  
*FORTN SOFTW LLC, 1998, TRANSFORM V3 4
[4]   Coupling high-pressure MALDI with ion mobility/orthogonal time-of flight mass spectrometry [J].
Gillig, KJ ;
Ruotolo, B ;
Stone, EG ;
Russell, DH ;
Fuhrer, K ;
Gonin, M ;
Schultz, AJ .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :3965-3971
[5]  
GONIN M, 2000, 12 SAN C MASS SPECTR
[6]   Combined ion mobility time-of-flight mass spectrometry study of electrospray-generated ions [J].
Guevremont, R ;
Siu, KWM ;
Wang, JY ;
Ding, LY .
ANALYTICAL CHEMISTRY, 1997, 69 (19) :3959-3965
[7]   ION MOBILITY SPECTROMETRY [J].
HILL, HH ;
SIEMS, WF ;
STLOUIS, RH ;
MCMINN, DG .
ANALYTICAL CHEMISTRY, 1990, 62 (23) :A1201-A1209
[8]  
Hoadlund-Hyzer CS, 2000, ANAL CHEM, V72, P2737
[9]   Three-dimensional ion mobility TOFMS analysis of electrosprayed biomolecules [J].
Hoaglund, CS ;
Valentine, SJ ;
Sporleder, CR ;
Reilly, JP ;
Clemmer, DE .
ANALYTICAL CHEMISTRY, 1998, 70 (11) :2236-2242
[10]   An ion trap interface for ESI-ion mobility experiments [J].
Hoaglund, CS ;
Valentine, SJ ;
Clemmer, DE .
ANALYTICAL CHEMISTRY, 1997, 69 (20) :4156-4161