Preneural limitations on letter identification in central and peripheral vision

被引:15
作者
Beckmann, PJ [1 ]
Legge, GE [1 ]
机构
[1] Univ Minnesota, Dept Psychol, Minneapolis, MN 55455 USA
来源
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION | 2002年 / 19卷 / 12期
关键词
D O I
10.1364/JOSAA.19.002349
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We created a sequential ideal-observer model that could address the question, How much of letter identification performance and its change with eccentricity can be accounted for by preneural factors? The ideal-observer model takes into account preneural factors including the stimulus rendering properties of a CRT display, the optical imaging quality of the eye, and photon capture and sampling characteristics of the cones. We validated the formulation of the model by comparing its performance on simple psychophysical tasks with that of previous sequential ideal-observer models. The model was used to study properties of the image rendering of letters. For example, the model's identification of high-resolution letters (i.e., many pixels per letter), but not low-resolution letters, is largely immune to changes in pixel width. We compared human and ideal-observer letter-identification acuity for the lowercase alphabet at 0degrees, 5degrees, and 20degrees retinal eccentricity. Acuity of the ideal observer for high-contrast letters is approximately seven times better than that of the human observers at 0degrees. Acuity decreased with eccentricity more rapidly for human observers than for the ideal observer such that the thresholds differed by a factor of 50 at 20degrees. A decrease in stimulus duration from 100 to 33 ms resulted in no decrease in relative threshold size between the human and ideal observers at all eccentricities, indicating that humans effectively integrate stimulus information over this range. Decreasing contrast from 75% to 25%, however, reduced the difference in acuities twofold at all eccentricities between humans and the ideal-observer model, consistent with the presence a compressive nonlinearity only in the human observers. The gap between human and ideal acuity in central vision means that there are substantial limitations in human letter recognition beyond the stage of photoreceptor sampling. The increasing performance gap between human and ideal-observer performance with eccentricity implicates an increasing role of neural limitations with eccentricity in limiting human letter identification. (C) 2002 Optical Society of America.
引用
收藏
页码:2349 / 2362
页数:14
相关论文
共 73 条
[41]   Psychophysics of reading XX. Linking letter recognition to reading speed in central and peripheral vision [J].
Legge, GE ;
Mansfield, JS ;
Chung, STL .
VISION RESEARCH, 2001, 41 (06) :725-743
[42]   VARIABILITY IN RESPONSES OF RETINAL GANGLION-CELLS [J].
LEVINE, MW ;
ZIMMERMAN, RP ;
CARRIONCARIRE, V .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1988, 5 (04) :593-597
[43]   PERIPHERAL ASTIGMATISM IN HUMAN EYE - EXPERIMENTAL-DATA AND THEORETICAL MODEL PREDICTIONS [J].
LOTMAR, W ;
LOTMAR, T .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1974, 64 (04) :510-513
[44]  
Ludvigh E., 1941, AM J OPHTHALMOL, V24, P303, DOI [DOI 10.1016/S0002-9394(41)90648-7, https://doi.org/10.1016/S0002-9394(41]
[45]   CONFIDENCE-INTERVALS FOR THE PARAMETERS OF PSYCHOMETRIC FUNCTIONS [J].
MALONEY, LT .
PERCEPTION & PSYCHOPHYSICS, 1990, 47 (02) :127-134
[46]   Coherent imaging of the cone mosaic in the living human eye [J].
Marcos, S ;
Navarro, R ;
Artal, P .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1996, 13 (05) :897-905
[47]   Distribution of astigmatism in the adult population [J].
McKendrick, AM ;
Brennan, NA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1996, 13 (02) :206-214
[48]   EFFECT OF DIOPTRICS ON PERIPHERAL VISUAL-ACUITY [J].
MILLODOT, M ;
JOHNSON, CA ;
LAMONT, A ;
LEIBOWITZ, HW .
VISION RESEARCH, 1975, 15 (12) :1357-1362
[49]   MODULATION TRANSFER OF THE HUMAN EYE AS A FUNCTION OF RETINAL ECCENTRICITY [J].
NAVARRO, R ;
ARTAL, P ;
WILLIAMS, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (02) :201-212
[50]   THE RATIO OF L-CONES TO M-CONES IN THE HUMAN PARAFOVEAL RETINA [J].
NERGER, JL ;
CICERONE, CM .
VISION RESEARCH, 1992, 32 (05) :879-888