Muscle Fat Fraction in Neuromuscular Disorders: Dual-Echo Dual-Flip-Angle Spoiled Gradient-Recalled MR Imaging Technique for Quantification-A Feasibility Study

被引:80
作者
Gaeta, Michele [1 ]
Scribano, Emanuele [1 ]
Mileto, Achille [1 ]
Mazziotti, Silvio [1 ]
Rodolico, Carmelo [2 ]
Toscano, Antonio [2 ]
Settineri, Nicola [1 ]
Ascenti, Giorgio [1 ]
Blandino, Alfredo [1 ]
机构
[1] Policlin G Martino, Dept Radiol Sci, I-98125 Messina, Italy
[2] Policlin G Martino, Dept Neurosci, I-98125 Messina, Italy
关键词
DUCHENNE MUSCULAR-DYSTROPHY; SKELETAL-MUSCLE; MAGNETIC-RESONANCE; LIVER STEATOSIS; DISEASE; SPECTROSCOPY; PHASE; DIXON;
D O I
10.1148/radiol.10101108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To prospectively evaluate the muscle fat fraction (MFF) measured with dual-echo dual-flip-angle spoiled gradient-recalled acquisition in the steady state (SPGR) magnetic resonance (MR) imaging technique by using muscle biopsy as the reference standard. Materials and Methods: After ethics approval, written informed consent from all patients was obtained. Twenty-seven consecutive patients, evaluated at the Neuromuscular Disorders Center with a possible diagnosis of neuromuscular disorder, were prospectively studied with MR imaging of the lower extremities to quantify muscle fatty infiltration by means of MFF calculation. Spin-density- and T1-weighted fast SPGR in-phase and opposed-phase dual-echo sequences were performed, respectively, with 20 degrees and 80 degrees flip angles. Round regions of interest were drawn by consensus on selected MR sections corresponding to anticipated biopsy sites. These were marked on the patient's skin with a pen by using the infrared spider light of the system, and subsequent muscle biopsy was performed. MR images with regions of interest were stored on a secondary console where the MFF calculation was performed by another radiologist blinded to the biopsy results. MFFs calculated with dual-echo dual-flip-angle SPGR MR imaging and biopsy were compared by using a paired t test, Pearson correlation coefficient, and Bland-Altman plots. P value of < .05 was considered to indicate a statistically significant difference. Results: The mean MFFs obtained with dual-echo dual-flip-angle SPGR MR imaging and biopsy were 20.3% (range, 1.7%-45.1%) and 20.6% (range, 3%-46.1%), respectively. The mean difference, standard deviation of the difference, and t value were -0.3, 1.3, and -1.3 (P >.2), respectively. The Pearson correlation coefficient was 0.995; with the Bland-Altman method, all data points were within the +/- 2 SDs limits of agreement. Conclusion: The results show that dual-echo dual-flip-angle SPGR MR imaging technique provides reliable calculation of MFF, consistent with biopsy measurements. (C) RSNA, 2011
引用
收藏
页码:487 / 494
页数:8
相关论文
共 34 条
[1]
Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload [J].
Anderson, LJ ;
Holden, S ;
Davis, B ;
Prescott, E ;
Charrier, CC ;
Bunce, NH ;
Firmin, DN ;
Wonke, B ;
Porter, J ;
Walker, JM ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2001, 22 (23) :2171-2179
[2]
[Anonymous], CORR
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
Nonalcoholic Fatty Liver Disease: Rapid Evaluation of Liver Fat Content with In-Phase and Out-of-Phase MR Imaging [J].
Borra, Ronald J. H. ;
Salo, Sakari ;
Dean, Kirsti ;
Lautamaki, Riikka ;
Nuutila, Pirjo ;
Komu, Markku ;
Parkkola, Riitta .
RADIOLOGY, 2009, 250 (01) :130-136
[5]
LOCALIZED PROTON NMR-SPECTROSCOPY USING STIMULATED ECHOES - APPLICATIONS TO HUMAN SKELETAL-MUSCLE INVIVO [J].
BRUHN, H ;
FRAHM, J ;
GYNGELL, ML ;
MERBOLDT, KD ;
HANICKE, W ;
SAUTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (01) :82-94
[6]
Relaxation effects in the quantification of fat using gradient echo imaging [J].
Bydder, Mark ;
Yokoo, Takeshi ;
Hamilton, Gavin ;
Middleton, Michael S. ;
Chavez, Alyssa D. ;
Schwimmer, Jeffrey B. ;
Lavine, Joel E. ;
Sirlin, Claude B. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (03) :347-359
[7]
SIGNAL-TO-NOISE RATIO AND SECTION THICKNESS IN TWO-DIMENSIONAL VERSUS 3-DIMENSIONAL FOURIER-TRANSFORM MR IMAGING [J].
CARLSON, J ;
CROOKS, L ;
ORTENDAHL, D ;
KRAMER, DM ;
KAUFMAN, L .
RADIOLOGY, 1988, 166 (01) :266-270
[8]
Fatty Liver Disease: MR Imaging Techniques for the Detection and Quantification of Liver Steatosis [J].
Cassidy, Fiona Hughes ;
Yokoo, Takeshi ;
Aganovic, Lejla ;
Hanna, Robert F. ;
Bydder, Mark ;
Middleton, Michael S. ;
Hamilton, Gavin ;
Chavez, Alyssa D. ;
Schwimmer, Jeffrey B. ;
Sirlin, Claude B. .
RADIOGRAPHICS, 2009, 29 (01) :231-260
[9]
Noninvasive quantitation of human liver steatosis using magnetic resonance and bioassay methods [J].
d'Assignies, Gaspard ;
Ruel, Martin ;
Khiat, Abdesslem ;
Lepanto, Luigi ;
Chagnon, Miguel ;
Kauffmann, Claude ;
Tang, An ;
Gaboury, Louis ;
Boulanger, Yvan .
EUROPEAN RADIOLOGY, 2009, 19 (08) :2033-2040
[10]
Fat suppression in MR imaging: Techniques and pitfalls [J].
Delfaut, EM ;
Beltran, J ;
Johnson, G ;
Rousseau, J ;
Marchandise, X ;
Cotten, A .
RADIOGRAPHICS, 1999, 19 (02) :373-382