Fatty Liver Disease: MR Imaging Techniques for the Detection and Quantification of Liver Steatosis

被引:220
作者
Cassidy, Fiona Hughes [1 ,3 ]
Yokoo, Takeshi [1 ]
Aganovic, Lejla [1 ,3 ]
Hanna, Robert F. [1 ]
Bydder, Mark [1 ]
Middleton, Michael S. [1 ]
Hamilton, Gavin [1 ]
Chavez, Alyssa D. [1 ]
Schwimmer, Jeffrey B. [2 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Div Gastroenterol Hepatol & Nutr, Dept Pediat, San Diego, CA 92103 USA
[3] VA Med Ctr, Dept Radiol, San Diego, CA USA
关键词
MAGNETIC-RESONANCE-SPECTROSCOPY; SPECTRAL-SPATIAL PULSES; GRADIENT-ECHO; DIXON TECHNIQUE; HEPATIC STEATOSIS; INHOMOGENEITY CORRECTION; RELAXATION-TIMES; 2-POINT DIXON; IN-VIVO; 3.0; T;
D O I
10.1148/rg.291075123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fatty liver disease is the most common cause of chronic liver disease in the United States. Noninvasive detection and quantification of fat is becoming more and more important clinically, due in large part to the growing prevalence of nonalcoholic fatty liver disease. Steatosis, the accumulation of fat-containing vacuoles within hepatocytes, is a key histologic feature of fatty liver disease. Liver biopsy, the current Standard of reference for the assessment of steatosis, is invasive, has sampling errors, and is not appropriate in some settings. Several magnetic resonance (MR) imaging-based techniques-including chemical shift imaging, frequency-selective imaging, and MR spectroscopy-are currently in clinical use for the detection and quantification of fat-water admixtures, with each technique having important advantages, disadvantages, and limitations. These techniques permit the breakdown of the net MR signal into fat and water signal components, allowing the quantification of fat in liver tissue, and are increasingly being used in the diagnosis, treatment, and follow-up of fatty liver disease.
引用
收藏
页码:231 / 260
页数:30
相关论文
共 47 条
[1]  
[Anonymous], 2004, HDB MRI PULSE SEQUEN, DOI 10.1016/B978-0-12-092861-3.X5000-6
[2]   A placebo-controlled trial of pioglitazone in subjects with nonalcoholic steatohepatitis [J].
Belfort, Renata ;
Harrison, Stephen A. ;
Brown, Kenneth ;
Darland, Celia ;
Finch, Joan ;
Hardies, Jean ;
Balas, Bogdan ;
Gastaldelli, Amalia ;
Tio, Fermin ;
Pulcini, Joseph ;
Berria, Rachele ;
Ma, Jennie Z. ;
Dwivedi, Sunil ;
Havranek, Russell ;
Fincke, Chris ;
DeFronzo, Ralph ;
Bannayan, George A. ;
Schenker, Steven ;
Cusi, Kenneth .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (22) :2297-2307
[3]   Comparison of fat quantification methods: A phantom study at 3.0T [J].
Bernard, Clare P. ;
Liney, Gary P. ;
Manton, David J. ;
Turnbull, Lindsay W. ;
Langton, Christian M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (01) :192-197
[4]   Consistent fat suppression with compensated spectral-spatial pulses [J].
Block, W ;
Pauly, J ;
Kerr, A ;
Nishimura, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :198-206
[5]   SPIN-LATTICE RELAXATION-TIME MEASUREMENT BY MEANS OF A TURBOFLASH TECHNIQUE [J].
BLUML, S ;
SCHAD, LR ;
STEPANOW, B ;
LORENZ, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :289-295
[6]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[7]   Three-point Dixon chemical-shift imaging for evaluating articular cartilage defects in the knee joint on a low-field-strength open magnet [J].
Bredella, MA ;
Losasso, C ;
Moelleken, SC ;
Huegli, RW ;
Genant, HK ;
Tirman, PFJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1371-1375
[8]   QUANTITATIVE PROTON CHEMICAL-SHIFT IMAGING [J].
BUXTON, RB ;
WISMER, GL ;
BRADY, TJ ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :881-900
[9]  
BYDDER M, 2006, P 14 M INT SOC MAGN, P2300
[10]   Relaxation effects in the quantification of fat using gradient echo imaging [J].
Bydder, Mark ;
Yokoo, Takeshi ;
Hamilton, Gavin ;
Middleton, Michael S. ;
Chavez, Alyssa D. ;
Schwimmer, Jeffrey B. ;
Lavine, Joel E. ;
Sirlin, Claude B. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (03) :347-359