Three-point Dixon chemical-shift imaging for evaluating articular cartilage defects in the knee joint on a low-field-strength open magnet

被引:20
作者
Bredella, MA
Losasso, C
Moelleken, SC
Huegli, RW
Genant, HK
Tirman, PFJ
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] San Francisco Magnet Resonance Ctr, San Francisco, CA 94118 USA
[3] Natl Orthoped Imaging Associates, Greenbrae, CA 94904 USA
关键词
D O I
10.2214/ajr.177.6.1771371
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to assess the value of a modified three-point Dixon MR technique for evaluating articular cartilage defects in the knee joint on a low-field-strength open magnet, correlated with arthroscopy. SUBJECTS AND METHODS: Twenty consecutive patients who underwent both MR imaging and arthroscopy of the knee joint for suspected internal derangement were examined. A modified three-point Dixon MR sequence with a single radiofrequency echo single-scan method for water and fat separation with correction of the static field inhomogeneities was performed on a 0.35-T open magnet to obtain fat suppression. The MR images were prospectively evaluated for the presence and grade of articular cartilage defects. RESULTS. Uniform fat suppression was obtained in all patients using the modified three-point Dixon technique. Fifty-nine cartilage abnormalities were identified in 19 patients on the basis of arthroscopy. Forty-seven of 59 arthroscopically proven abnormalities were prospectively detected on MR imaging. Compared with arthroscopy, the overall sensitivity of the modified three-point Dixon technique in detecting cartilage lesions was 80% and the specificity was 73%. Sixty-five percent of the cartilage abnormalities were graded identically on MR imaging and arthroscopy. CONCLUSION. The modified three-point Dixon sequence is a useful technique for achieving fat suppression in the knee joint on a 0.35-T open magnet. It is a sensitive and specific technique :for the assessment of cartilage abnormalities in the knee.
引用
收藏
页码:1371 / 1375
页数:5
相关论文
共 22 条
[1]   Evaluation of patellar cartilage in cadavers with a low-field-strength extremity-only magnet: Comparison of MR imaging sequences, with macroscopic findings as the standard [J].
Ahn, JM ;
Kwak, SM ;
Kang, HS ;
Muhle, C ;
Pedowitz, PA ;
Frank, LR ;
Trudell, D ;
Haghighi, P ;
Resnick, D .
RADIOLOGY, 1998, 208 (01) :57-62
[2]   Quantitative assessment of bone marrow hematopoiesis using parametric magnetic resonance imaging [J].
Ballon, D ;
Jakubowski, AA ;
Tulipano, PK ;
Graham, MC ;
Schneider, E ;
Aghazadeh, B ;
Chen, QS ;
Koutcher, JA .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (05) :789-800
[3]   Incidentally discovered adrenal masses: Evaluation with Gadolinium enhancement and fat-suppressed MR imaging at 0.5 T [J].
Boraschi, P ;
Braccini, G ;
Grassi, L ;
Campatelli, A ;
DiVito, A ;
Mosca, F ;
Perri, G .
EUROPEAN JOURNAL OF RADIOLOGY, 1997, 24 (03) :245-252
[4]   Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients [J].
Bredella, MA ;
Tirman, PFJ ;
Peterfy, CG ;
Zarlingo, M ;
Feller, JF ;
Bost, FW ;
Belzer, JP ;
Wischer, TK ;
Genant, HK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1073-1080
[5]   Short echo time projection reconstruction MR imaging of cartilage: Comparison with fat-suppressed spoiled GRASS and magnetization transfer contrast MR imaging [J].
Brossmann, J ;
Frank, LR ;
Pauly, JM ;
Boutin, RD ;
Pedowitz, RA ;
Haghighi, P ;
Resnick, D .
RADIOLOGY, 1997, 203 (02) :501-507
[6]   Two-point dixon technique for water-fat signal decomposition with B-o inhomogeneity correction [J].
Coombs, BD ;
Szumowski, J ;
Coshow, W .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :884-889
[7]   MR imaging of the knee at 0.2 and 1.5 T:: Correlation with surgery [J].
Cotten, A ;
Delfaut, E ;
Demondion, X ;
Lapègue, F ;
Boukhelifa, M ;
Boutry, N ;
Chastanet, P ;
Gougeon, F .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :1093-1097
[8]   DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY [J].
DISLER, DG ;
MCCAULEY, TR ;
WIRTH, CR ;
FUCHS, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :377-382
[9]   Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy [J].
Disler, DG ;
McCauley, TR ;
Kelman, CG ;
Fuchs, MD ;
Ratner, LM ;
Wirth, CR ;
Hospodar, PP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :127-132
[10]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194