A multi-ion particle sensor

被引:47
作者
Ruedas-Rama, Maria Jose [1 ]
Wang, Xiaojuan [1 ]
Hall, Elizabeth A. H. [1 ]
机构
[1] Univ Cambridge, Inst Biotechnol, Cambridge CB2 1QT, England
基金
英国生物技术与生命科学研究理事会;
关键词
RESONANCE ENERGY-TRANSFER; QUANTUM DOTS; FLUORESCENCE; MICROSPHERES; ACCEPTORS; DONORS;
D O I
10.1039/b618514b
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The first sub-micron polyacrylic sensor containing two independent ion-sensing systems is shown, that uses a single excitation wavelength and separates signals by using quantum dot donors to form FRET pairs with other fluorophores.
引用
收藏
页码:1544 / 1546
页数:3
相关论文
共 18 条
[1]   Ultra-high-throughput screening based on cell-surface display and fluorescence-activated cell sorting for the identification of novel biocatalysts [J].
Becker, S ;
Schmoldt, HU ;
Adams, TM ;
Wilhelm, S ;
Kolmar, H .
CURRENT OPINION IN BIOTECHNOLOGY, 2004, 15 (04) :323-329
[2]   Fluorescence resonance energy transfer between quantum dot donors and dye-labeled protein acceptors [J].
Clapp, AR ;
Medintz, IL ;
Mauro, JM ;
Fisher, BR ;
Bawendi, MG ;
Mattoussi, H .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (01) :301-310
[3]   Quantum dot-based multiplexed fluorescence resonance energy transfer [J].
Clapp, AR ;
Medintz, IL ;
Uyeda, HT ;
Fisher, BR ;
Goldman, ER ;
Bawendi, MG ;
Mattoussi, H .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (51) :18212-18221
[4]   Can luminescent quantum dots be efficient energy acceptors with organic dye donors? [J].
Clapp, AR ;
Medintz, IL ;
Fisher, BR ;
Anderson, GP ;
Mattoussi, H .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (04) :1242-1250
[5]   Multiplexed toxin analysis using four colors of quantum dot fluororeagents [J].
Goldman, ER ;
Clapp, AR ;
Anderson, GP ;
Uyeda, HT ;
Mauro, JM ;
Medintz, IL ;
Mattoussi, H .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :684-688
[6]   Optical sensor for seawater salinity [J].
Huber, C ;
Klimant, I ;
Krause, C ;
Werner, T ;
Mayr, T ;
Wolfbeis, OS .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (2-3) :196-202
[7]   Serum chloride optical sensors based on dynamic quenching of the fluorescence of photo-immobilized lucigenin [J].
Huber, C ;
Krause, C ;
Werner, T ;
Wolfbeis, OS .
MICROCHIMICA ACTA, 2003, 142 (04) :245-253
[8]   Multi-ion imaging using fluorescent sensors in a microtiterplate array format [J].
Mayr, T ;
Liebsch, G ;
Klimant, I ;
Wolfbeis, OS .
ANALYST, 2002, 127 (02) :201-203
[9]   Solution-phase single quantum dot fluorescence resonance energy transfer [J].
Pons, Thomas ;
Medintz, Igor L. ;
Wang, Xiang ;
English, Douglas S. ;
Mattoussi, Hedi .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (47) :15324-15331
[10]   A flow-injection renewable surface sensor for the fluorimetric determination of vanadium(V) with Alizarin Red S [J].
Rama, MJR ;
Medina, AR ;
Díaz, AM .
TALANTA, 2005, 66 (05) :1333-1339