Effective delivery of particles with the HandiHaler® dry powder inhalation system over a range of chronic obstructive pulmonary disease severity

被引:92
作者
Chodosh, S [1 ]
Flanders, JS [1 ]
Kesten, S [1 ]
Serby, CW [1 ]
Hochrainer, D [1 ]
Witek, TJ [1 ]
机构
[1] Vet Adm Outpatient Clin, Boston, MA USA
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2001年 / 14卷 / 03期
关键词
COPD; dry powder; flow rates; inhalation;
D O I
10.1089/089426801316970268
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The HandiHaler((R)) is a dry powder breath activated inhaler system developed for inhalation therapy for patients with airway disease. Its operation is based on the evacuation of powder from a pierced capsule. We sought to document the inspiratory flow rates attained by patients inspiring through the HandiHaler((R)) with various degrees of airflow limitation. Subjects with stable chronic obstructive pulmonary disease (COPD) were the study's population. An in vitro study of fine particle dose was conducted using an Andersen Cascade Impactor to assess medication delivery at low inspiratory flow rates. Subsequently, an in vivo study was conducted to determine inspiratory flow rates in patients with COPD as measured through a pneumotach with a custom coupler device with and without the HandiHaler (R). Patients were classified into three approximately equal groups of spirometric severity ranging from mild (46-65% predicted normal forced expiratory volume in 1 sec [FEV1]), to moderate (28-45%) to severe (less than or equal to 27%). The in vitro study indicated delivery of medication at flow rates as low as 20 L/min. Twenty-six men completed the in vivo study (age 66.9 +/- 10.9 years, FEV1 = 1.02 +/- 0.45 1.). The median peak inspiratory flow rates attained in the mild (n = 8), moderate (n = 10), and severe (n = 8) categories were 45, 45.6, and 35.4 L/min respectively. The minimum peak inspiratory flow rates in the three groups were 28.2, 21.6 and 20.4 L/min. The HandiHaler((R)) device effectively delivers particles to the lung over a wide range of airflow limitation in patients with COPD.
引用
收藏
页码:309 / 315
页数:7
相关论文
共 19 条
[1]  
*AM THOR SOC, 1995, AM J RESP CRIT CARE, V152, pS84
[2]  
Barnes PJ, 2000, CHEST, V117, P63
[3]   LUNG DEPOSITION OF BUDESONIDE INHALED VIA TURBUHALER(R) - A COMPARISON WITH TERBUTALINE SULFATE IN NORMAL SUBJECTS [J].
BORGSTROM, L ;
BONDESSON, E ;
MOREN, F ;
TROFAST, E ;
NEWMAN, SP .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (01) :69-73
[4]  
Chrystyn H, 1999, CLIN DRUG INVEST, V18, P403
[5]   THE RELATIONSHIP BETWEEN POWDER INHALER RESISTANCE AND PEAK INSPIRATORY CONDITIONS IN HEALTHY-VOLUNTEERS - IMPLICATIONS FOR IN-VITRO TESTING [J].
CLARK, AR ;
HOLLINGWORTH, AM .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1993, 6 (02) :99-110
[6]   Peak inspiratory flow through Turbuhaler® in chronic obstructive airways disease [J].
Dewar, MH ;
Jamieson, A ;
McLean, A ;
Crompton, GK .
RESPIRATORY MEDICINE, 1999, 93 (05) :342-344
[7]   MEDICAL PERSONNELS KNOWLEDGE OF AND ABILITY TO USE INHALING DEVICES - METERED-DOSE INHALERS, SPACING CHAMBERS, AND BREATH-ACTUATED DRY POWDER INHALERS [J].
HANANIA, NA ;
WITTMAN, R ;
KESTEN, S ;
CHAPMAN, KR .
CHEST, 1994, 105 (01) :111-116
[8]   A comparison of the performance of two modern multidose dry powder asthma inhalers [J].
Hill, LS ;
Slater, AL .
RESPIRATORY MEDICINE, 1998, 92 (01) :105-110
[9]   PATIENT HANDLING OF A MULTIDOSE DRY POWDER INHALATION DEVICE FAR ALBUTEROL [J].
KESTEN, S ;
ELIAS, M ;
CARTIER, A ;
CHAPMAN, KR .
CHEST, 1994, 105 (04) :1077-1081
[10]   EVALUATION OF CONVENTIONAL PRESS-AND-BREATHE METERED-DOSE INHALER TECHNIQUE IN 501 PATIENTS [J].
LARSEN, JS ;
HAHN, M ;
EKHOLM, B ;
WICK, KA .
JOURNAL OF ASTHMA, 1994, 31 (03) :193-199