Improved Bayesian image estimation for digital chest radiography

被引:16
作者
Baydush, AH
Bowsher, JE
Laading, JK
Floyd, CE
机构
[1] DUKE UNIV,INST STAT & DECIS SCI,DURHAM,NC 27706
[2] DUKE UNIV,DEPT BIOMED ENGN,DURHAM,NC 27706
关键词
scatter reduction; digital thoracic imaging; statistical image processing;
D O I
10.1118/1.598054
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Previously, we have shown that Spatially Varying Bayesian Image Estimation (SVBIE) can be used to reduce scatter and improve contrast-to-noise ratios (CNR) in digital chest radiographs with no degradation of image resolution. This previous algorithm used a model for scatter compensation that was derived for emission tomography. Here, we develop and evaluate a new iterative SVBIE technique that incorporates a scatter model derived for projection radiography. Materials and Methods: Portable digital radiographs of an anthropomorphic chest phantom were obtained along with quantitative scatter measurements using a calibrated photostimulable phosphor system. The new iterative SVBIE technique was applied to the phantom image to reduce scatter. Scatter fraction reduction, CNR improvement, and resolution degradation were evaluated. Results: Residual scatter fractions were reduced to less than 2% in the lungs and 30% in the mediastinum at 14 iterations. CNR was improved by approximately 50% in the lung region and 187% in the mediastinum. Resolution was not degraded. Conclusions: The new SVBIE technique can reduce scatter to levels far below those provided by an antiscatter grid and can increase CNR without loss of resolution. The new technique outperforms the previous Bayesian techniques. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:539 / 545
页数:7
相关论文
共 19 条
  • [1] BAYESIAN IMAGE ESTIMATION OF DIGITAL CHEST RADIOGRAPHY - INTERDEPENDENCE OF NOISE, RESOLUTION, AND SCATTER FRACTION
    BAYDUSH, AH
    FLOYD, CE
    [J]. MEDICAL PHYSICS, 1995, 22 (08) : 1255 - 1261
  • [2] Spatially varying Bayesian image estimation
    Baydush, AH
    Floyd, CE
    [J]. ACADEMIC RADIOLOGY, 1996, 3 (02) : 129 - 136
  • [3] CHARACTERIZATION OF THE POINT SPREAD FUNCTION AND MODULATION TRANSFER-FUNCTION OF SCATTERED RADIATION USING A DIGITAL IMAGING-SYSTEM
    BOONE, JM
    ARNOLD, BA
    SEIBERT, JA
    [J]. MEDICAL PHYSICS, 1986, 13 (02) : 254 - 256
  • [4] APPLICATION OF THE EM-ALGORITHM TO RADIOGRAPHIC IMAGES
    BRAILEAN, JC
    LITTLE, D
    GIGER, ML
    CHEN, CT
    SULLIVAN, BJ
    [J]. MEDICAL PHYSICS, 1992, 19 (05) : 1175 - 1182
  • [5] MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM
    DEMPSTER, AP
    LAIRD, NM
    RUBIN, DB
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01): : 1 - 38
  • [6] BAYESIAN RESTORATION OF CHEST RADIOGRAPHS - SCATTER COMPENSATION WITH IMPROVED SIGNAL-TO-NOISE RATIO
    FLOYD, CE
    BAYDUSH, AH
    LO, JY
    BOWSHER, JE
    RAVIN, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 (10) : 904 - 910
  • [7] SCATTER COMPENSATION FOR DIGITAL CHEST RADIOGRAPHY USING MAXIMUM-LIKELIHOOD EXPECTATION MAXIMIZATION
    FLOYD, CE
    BAYDUSH, AH
    LO, JY
    BOWSHER, JE
    RAVIN, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (05) : 427 - 433
  • [8] MEASUREMENT OF SCATTER FRACTIONS IN CLINICAL BEDSIDE RADIOGRAPHY
    FLOYD, CE
    BAKER, JA
    LO, JY
    RAVIN, CE
    [J]. RADIOLOGY, 1992, 183 (03) : 857 - 861
  • [9] POSTERIOR BEAM-STOP METHOD FOR SCATTER FRACTION MEASUREMENT IN DIGITAL RADIOGRAPHY
    FLOYD, CE
    BAKER, JA
    LO, JY
    RAVIN, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 (02) : 119 - 123
  • [10] SCATTER COMPENSATION IN DIGITAL CHEST RADIOGRAPHY USING FOURIER DECONVOLUTION
    FLOYD, CE
    BEATTY, PT
    RAVIN, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1989, 24 (01) : 30 - 33