An account of the discrepancy between MRI and PET cerebral blood flow measures. A high-field MRI investigation

被引:77
作者
Donahue, Manus J.
Lu, Hanzhang
Jones, Craig K.
Pekar, James J.
van Zijl, Peter C. M.
机构
[1] Johns Hopkins Univ, Russell H Morgan Dept Radiol & Radiol Sci, Div MR Res, Baltimore, MD 21205 USA
[2] Kennedy Krieger Inst, FM Kirby Res Ctr Funct Brain Imaging, Baltimore, MD USA
[3] Johns Hopkins Univ, Dept Biophys & Biophys Chem, Baltimore, MD USA
[4] NYU, Dept Radiol, New York, NY 10016 USA
关键词
perfusion; arterial spin labeling; cerebral blood flow; partial volume;
D O I
10.1002/nbm.1075
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
There is controversy concerning the discrepancy between absolute cerebral blood flow (CBF) values measured using positron emission tomography (PET) and magnetic resonance imaging (MRI). To gain insight into this problem, the increased signal-to-noise ratio (SNR) and extended T-1 relaxation times of blood and tissue at 3.0 T were exploited to perform pulsed arterial spin labeling (PASL) MRI measurements as a function of spatial resolution and post-labeling delay. The results indicate that, when using post-labeling delays shorter than 1500 ins, MRI gray matter flow values may become as high as several times the correct CBF values owing to tissue signal contamination by remaining arterial blood water label. For delays above 1500 ms. regional PASL-based CBF values (n = 5; frontal gray matter: 48.8 +/- 3.3(SD) ml/100 g/min; occipital,gray matter: 49.3 +/- 4.5 ml/100 a min) comparable with PET-based measurements can be obtained by using spatial resolutions comparable with PET (5-7.5 mm in-plane). At very high resolution (2.5 x 2.5 x 3 mm(3)), gray matter CBF values were found to increase by 10-20%, a consequence attributed to reduction in partial volume effects with cerebrospinal fluid and white matter. The recent availability of MRI field strengths of 3.0 T and higher will facilitate the use of MRI-based CBF measurements in the clinic. Copyright (C) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1043 / 1054
页数:12
相关论文
共 46 条
[31]   Regional differences in the CBF and BOLD responses to hypercapnia: A combined PET and fMRI study [J].
Rostrup, E ;
Law, I ;
Blinkenberg, M ;
Larsson, HBW ;
Born, AP ;
Holm, S ;
Paulson, OB .
NEUROIMAGE, 2000, 11 (02) :87-97
[32]   Effect of vascular crushing on FAIR perfusion kinetics, using a BIR-4 pulse in a magnetization prepared FLASH sequence [J].
Schepers, J ;
van Osch, MJP ;
Nicolay, K .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (03) :608-613
[33]   Estimation of water extraction fractions in rat brain using magnetic resonance measurement of perfusion with arterial spin labeling [J].
Silva, AC ;
Zhang, WG ;
Williams, DS ;
Koretsky, AP .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :58-68
[34]  
St Lawrence KS, 2000, MAGN RESON MED, V44, P440, DOI 10.1002/1522-2594(200009)44:3<440::AID-MRM15>3.0.CO
[35]  
2-6
[36]   INDIVIDUAL INTEGRATION OF POSITRON EMISSION TOMOGRAPHY AND HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING [J].
STEINMETZ, H ;
HUANG, YX ;
SEITZ, RJ ;
KNORR, U ;
SCHLAUG, G ;
HERZOG, H ;
HACKLANDER, T ;
FREUND, HJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1992, 12 (06) :919-926
[37]   Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 tesla [J].
Wang, JJ ;
Alsop, DC ;
Li, L ;
Listerud, J ;
Gonzalez-At, JB ;
Schnall, MD ;
Detre, JA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :242-254
[38]   MAGNETIC-RESONANCE-IMAGING OF PERFUSION USING SPIN INVERSION OF ARTERIAL WATER [J].
WILLIAMS, DS ;
DETRE, JA ;
LEIGH, JS ;
KORETSKY, AP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (01) :212-216
[39]  
Wong EC, 1999, NEUROIMAG CLIN N AM, V9, P333
[40]   Automated image registration: I. General methods and intrasubject, intramodality validation [J].
Woods, RP ;
Grafton, ST ;
Holmes, CJ ;
Cherry, SR ;
Mazziotta, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (01) :139-152