The use of continuous regularization in the automated analysis of MRS time-domain data

被引:10
作者
Totz, J
vandenBoogaart, A
VanHuffel, S
GraveronDemilly, D
Dologlou, I
Heidler, R
Michel, D
机构
[1] CATHOLIC UNIV LEUVEN,FAC MED,DEPT RADIOL,BIOMED NMR UNIT,B-3000 LOUVAIN,BELGIUM
[2] KATHOLIEKE UNIV LEUVEN,DEPT ELECT ENGN,ESAT,B-3001 LOUVAIN,BELGIUM
[3] UNIV LYON 1,CPE,CNRS UPRESA 5012,LAB RMN,F-69622 VILLEURBANNE,FRANCE
[4] NATL TECH UNIV ATHENS,GR-15773 ZOGRAFOS,GREECE
关键词
D O I
10.1006/jmre.1996.1043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, it is shown how the advantages of continuous regularization (CR) can be exploited to achieve an improved, fully automated LPSVD analysis of MRS time-domain data. The main advantage of CR is its ability to determine the number of spectral components even at low signal-to-noise ratios, which suggested its use for in vivo spectroscopy, Estimation of the spectral parameters is possible. Two alternatives of automated data-analysis schemes are thoroughly investigated by means of Monte Carlo studies. The results suggest the combination of CR for model-order estimation with other methods for more-accurate parameter estimation, Several possible combinations, including those with an improved enhancement procedure and a total-least-squares method for quantitation, are discussed, Recommendations are given for spectral analysis, and a new data-analysis protocol which performs significantly better than previously used protocols of the same type is proposed, (C) 1997 Academic Press.
引用
收藏
页码:400 / 409
页数:10
相关论文
共 15 条
[1]   RETRIEVAL OF FREQUENCIES, AMPLITUDES, DAMPING FACTORS, AND PHASES FROM TIME-DOMAIN SIGNALS USING A LINEAR LEAST-SQUARES PROCEDURE [J].
BARKHUIJSEN, H ;
DEBEER, R ;
BOVEE, WMMJ ;
VANORMONDT, D .
JOURNAL OF MAGNETIC RESONANCE, 1985, 61 (03) :465-481
[2]   SIGNAL ENHANCEMENT - A COMPOSITE PROPERTY MAPPING ALGORITHM [J].
CADZOW, JA .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1988, 36 (01) :49-62
[3]   QUALITY ASSESSMENT IN IN-VIVO NMR-SPECTROSCOPY .6. MULTICENTER QUANTIFICATION OF MRS TEST SIGNALS [J].
DEBEER, R ;
BACHERTBAUMANN, P ;
BOVEE, WMMJ ;
CADY, E ;
CHAMBRON, J ;
DOMMISSE, R ;
VANECHTELD, CJA ;
MATHURDEVRE, R ;
WILLIAMS, SR .
MAGNETIC RESONANCE IMAGING, 1995, 13 (01) :169-176
[4]  
DEBEER R, 1992, NMR BASIC PRINCIPLES, V26
[5]   AUTOMATIC INVIVO NMR DATA-PROCESSING BASED ON AN ENHANCEMENT PROCEDURE AND LINEAR PREDICTION METHOD [J].
DIOP, A ;
BRIGUET, A ;
GRAVERONDEMILLY, D .
MAGNETIC RESONANCE IN MEDICINE, 1992, 27 (02) :318-328
[6]   FULL AUTOMATION OF QUANTITATION OF IN-VIVO NMR BY LPSVD(CR) AND EPLPSVD [J].
DIOP, A ;
KOLBEL, W ;
MICHEL, D ;
BRIGUET, A ;
GRAVERONDEMILLY, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :217-221
[7]  
DOLOGLOU I, 1996, IN PRESS SIGNAL PROC
[8]  
KENDALL MG, 1979, ADV THEORY STATISTIC, V1
[9]   IMPROVEMENT AND AUTOMATION OF THE LPSVD ALGORITHM BY CONTINUOUS REGULARIZATION OF THE SINGULAR-VALUES [J].
KOLBEL, W ;
SCHAFER, H .
JOURNAL OF MAGNETIC RESONANCE, 1992, 100 (03) :598-603
[10]   ESTIMATING THE PARAMETERS OF EXPONENTIALLY DAMPED SINUSOIDS AND POLE-ZERO MODELING IN NOISE [J].
KUMARESAN, R ;
TUFTS, DW .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1982, 30 (06) :833-840