Exhaled Air Dispersion Distances During Noninvasive Ventilation via Different Respironics Face Masks

被引:97
作者
Hui, David S. [1 ]
Chow, Benny K. [1 ,2 ]
Ng, Susanna S. [1 ]
Chu, Leo C. Y. [3 ,4 ]
Hall, Stephen D. [5 ]
Gin, Tony [3 ,4 ]
Sung, Joseph J. Y. [1 ]
Chan, Matthew T. V. [3 ,4 ]
机构
[1] Chinese Univ Hong Kong, Dept Med & Therapeut, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Ctr Honsing Innovat, Shatin, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Inst Space & Earth Informat Sci, Shatin, Hong Kong, Peoples R China
[4] Chinese Univ Hong Kong, Dept Anesthesia & Intens Care, Shatin, Hong Kong, Peoples R China
[5] Univ New S Wales, Sch Mech Engn, Sydney, NSW, Australia
关键词
POSITIVE-PRESSURE VENTILATION; ACUTE RESPIRATORY SYNDROME; INFLUENZA A/H5N1 INFECTION; A H5N1 VIRUS; PATIENT SIMULATOR; OXYGEN DELIVERY; HONG-KONG; TRANSMISSION; OUTBREAK; DISEASE;
D O I
10.1378/chest.09-0434
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: As part of our influenza pandemic preparedness, we studied the exhaled air dispersion distances and directions through two different face masks (Respironics; Murrysville, PA) attached to a human-patient simulator (HPS) during noninvasive positive-pressure ventilation (NPPV) in an isolation room with pressure of -5 Pa. Methods: The HPS was positioned at 45 degrees on the bed and programmed to mimic mild lung injury (oxygen consumption, 300 mL/min; lung compliance, 35 mL/cm H2O. Airflow was marked with intrapulmonary smoke for visualization. Inspiratory positive airway pressure (IPAP) started at 10 cm H2O and gradually increased to 18 cm H2O, whereas expiratory pressure was maintained at 4 cm H2O. A leakage jet plume was revealed by a laser light sheet, and images were captured by high definition video. Normalized exhaled air concentration in the plume was estimated from the light scattered by the smoke particles. Findings: As IPAP increased from 10 to 18 cm H2O, the exhaled air of a low normalized concentration through the ComfortFull 2 mask (Respironics) increased from 0.65 to 0.85 m at a direction perpendicular to the head of the HPS along the median sagittal plane. When the IPAP of 10 cm H2O was applied via the Image 3 mask (Respironics) connected to the whisper swivel, the exhaled air dispersed to 0.95 m toward the end of the bed along the median sagittal plane, whereas higher IPAP resulted in wider spread of a higher concentration of smoke. Conclusions: Substantial exposure to exhaled air occurs within a 1-m region, from patients rec eiving NPPV via the ComfortFull 2 mask and the Image 3 mask, with more diffuse leakage from the latter, especially at higher IPA-P. (CHEST 2009; 136:998-1005)
引用
收藏
页码:998 / 1005
页数:8
相关论文
共 31 条
[11]   Airflows around oxygen masks - A potential source of infection? [J].
Hui, David S. ;
Ip, Margaret ;
Tang, Julian W. ;
Wong, Alexandra L. N. ;
Chan, Matthew T. V. ;
Hall, Stephen D. ;
Chan, Paul K. S. ;
Sung, Joseph J. Y. .
CHEST, 2006, 130 (03) :822-826
[12]   Noninvasive positive-pressure ventilation - An experimental model to assess air and particle dispersion [J].
Hui, David S. ;
Hall, Stephen D. ;
Chan, Matthew T. V. ;
Chow, Benny K. ;
Tsou, Jin Y. ;
Joynt, Gavin M. ;
Sullivan, Colin E. ;
Sung, Joseph J. Y. .
CHEST, 2006, 130 (03) :730-740
[13]   Exhaled Air and Aerosolized Droplet Dispersion During Application of a Jet Nebulizer [J].
Hui, David S. ;
Chow, Benny K. ;
Chu, Leo C. Y. ;
Ng, Susanna S. ;
Hall, Stephen D. ;
Gin, Tony ;
Chan, Matthew T. V. .
CHEST, 2009, 135 (03) :648-654
[14]   Influenza A/H5N1 infection: Other treatment options and issues [J].
Hui, David S. C. .
RESPIROLOGY, 2008, 13 :S22-S26
[15]   Review of clinical symptoms and spectrum in humans with influenza A/H5N1 infection [J].
Hui, David S. -C. .
RESPIROLOGY, 2008, 13 :S10-S13
[16]   Breathing pattern and workload during automatic tube compensation, pressure support and T-piece trials in weaning patients [J].
Kuhlen, R ;
Max, M ;
Dembinski, R ;
Terbeck, S ;
Jürgens, E ;
Rossaint, R .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2003, 20 (01) :10-16
[17]   An audible indication of exhalation increases delivered tidal volume during bag valve mask ventilation of a patient simulator [J].
Lampotang, S ;
Lizdas, DE ;
Gravenstein, N ;
Robicsek, S .
ANESTHESIA AND ANALGESIA, 2006, 102 (01) :168-171
[18]   A major outbreak of severe acute respiratory syndrome in Hong Kong [J].
Lee, N ;
Hui, D ;
Wu, A ;
Chan, P ;
Cameron, P ;
Joynt, GM ;
Ahuja, A ;
Yung, MY ;
Leung, CB ;
To, KF ;
Lui, SF ;
Szeto, CC ;
Chung, S ;
Sung, JJY .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (20) :1986-1994
[19]   Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review [J].
Li, Y. ;
Leung, G. M. ;
Tang, J. W. ;
Yang, X. ;
Chao, C. Y. H. ;
Lin, J. Z. ;
Lu, J. W. ;
Nielsen, P. V. ;
Niu, J. ;
Qian, H. ;
Sleigh, A. C. ;
Su, H. -J. J. ;
Sundell, J. ;
Wong, T. W. ;
Yuen, P. L. .
INDOOR AIR, 2007, 17 (01) :2-18
[20]  
Light R B, 1999, Semin Respir Infect, V14, P218