Direct injection micellar liquid chromatographic determination of benzodiazepines in serum

被引:46
作者
Capella-Peiró, ME
Bose, D
Martinavarro-Domínguez, A
Gil-Agustí, M
Esteve-Romero, J [1 ]
机构
[1] Univ Jaume 1, Area Quim Analit, Castellon de La Plana 12080, Spain
[2] Dr Hari Singh Gour Vishwavidyalaya, Dept Criminol & Forens Sci, Sagar, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 780卷 / 02期
关键词
benzodiazepines;
D O I
10.1016/S1570-0232(02)00523-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple micellar liquid chromatographic (MLC) procedure is reported for the determination of several benzodiazepines in serum: bromazepam, diazepam, flunitrazepam, halazepam, medazepam, nitrazepam, oxazeparn and tetrazepam. The optimization studies have been made in C-18 and C-8 columns, using solutions containing sodium dodecyl sulphate (SDS) modified with butanol or pentanol as mobile phases. The method proposed for the determination of the benzodiazepines uses a hybrid micellar mobile phase of 0.06 M SDS-5% butanol-0.01 M phosphate buffer (pH 7) at 25degreesC, and UV detection (230 nm) in a C-18 column. The serum samples were injected directly, without any pretreatment, and eluted in less than 22 min, in accordance with their relative polarities, as indicated by their octanol-water partition coefficients. The limits of detection (ng ml(-1)) were within the ranges of 2-6 and 4-18 for aqueous and serum samples, respectively. Repeatability and intermediate precision were tested for three different concentrations of the drugs, and RSD (%) was below 10 for most of the assays. The MLC results were compared with those obtained from a conventional HPLC method using methanol-water 5:5 (v/v) which requires a previous extraction procedure. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:241 / 249
页数:9
相关论文
共 26 条
[21]  
2-Q
[22]  
SHADER RI, 1977, AM J PSYCHIAT, V134, P652
[23]   Simultaneous determination of twelve benzodiazepines in human serum using a new reversed-phase chromatographic column on a 2-mu m porous microspherical silica gel [J].
Tanaka, E ;
Terada, M ;
Misawa, S ;
Wakasugi, C .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 682 (01) :173-178
[24]   Solid-phase microextraction for the analysis of biological samples [J].
Theodoridis, G ;
Koster, EHM ;
de Jong, GJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 745 (01) :49-82
[25]  
Torres-Cartas S, 1995, ANAL CHIM ACTA, V302, P163
[26]   Reversed-phase ion-pair HPLC method for the direct analysis of 1-OH midazolam glucuronide in human serum [J].
van Rij, KM ;
Compas, D ;
Swart, EL ;
de Goede, PNFC ;
Touw, DJ .
THERAPEUTIC DRUG MONITORING, 1999, 21 (04) :416-420