Continuous measurements of a binding reaction using a capacitive biosensor

被引:42
作者
Hedström, M [1 ]
Galaev, IY [1 ]
Mattiasson, B [1 ]
机构
[1] Lund Univ, Ctr Chem & Chem Engn, Dept Biotechnol, SE-22100 Lund, Sweden
关键词
capacitive biosensor; integral protein-binding curves; mathematical model; deconvolution;
D O I
10.1016/j.bios.2004.10.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A capacitive biosensor with polyclonal antibodies raised against human serum albumin (HSA) immobilized on a gold transducer has been developed for continuous measurement of HSA in the mu M-range. A mathematical model has been refined to describe integral HSA-binding curves assuming that (i) binding is essentially irreversible under the conditions used, (ii) the signal is scaled as the number of non-occupied binding sites and (iii) the rate of disappearance of available binding sites is scaled as the number of available binding sites and analyte concentration in solution. Deconvolution of the curves using the mathematical model indicates clearly that it is possible to retrieve concentration profiles (isocratic, linearly or exponentially increasing gradients) of the analyte in the continuous sample flow from the normalized integral binding (NIB) curves. The data presented constitutes the theoretical background and the first step towards the development of an analytical system allowing on-line detection of the concentration profile of the analyte from NIB-curves. Since the system can be used for extended time periods between regeneration steps, a low frequency of regeneration steps can be expected. (c) 2004 Published by Elsevier B.V.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 28 条
[1]  
BARD AJ, 1989, ELECTROCHEMICAL METH
[2]   An immunological interleukin-6 capacitive biosensor using perturbation with a potentiostatic step [J].
Berggren, C ;
Bjarnason, B ;
Johansson, G .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (10) :1061-1068
[3]   Instrumentation for direct capacitive biosensors [J].
Berggren, C ;
Bjarnason, B ;
Johansson, G .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 1999, 27 (02) :131-139
[4]  
BONTIDEAN I, 2001, ANGEW CHEM, V113, P2748
[5]  
DOBLHOFER K, 1994, T SAEST, V29, P181
[6]   Self-assembled monolayers of thiols on gold electrodes for bioelectrochemistry and biosensors [J].
Dong, SJ ;
Li, JH .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 42 (01) :7-13
[7]   Functionalized self-assembled alkanethiol monolayers on Au(111) electrodes:: 1.: Surface structure and electrochemistry [J].
Esplandiú, MJ ;
Hagenström, H ;
Kolb, DM .
LANGMUIR, 2001, 17 (03) :828-838
[8]   BIOSPECIFIC INTERACTION ANALYSIS USING SURFACE-PLASMON RESONANCE DETECTION APPLIED TO KINETIC, BINDING-SITE AND CONCENTRATION ANALYSIS [J].
FAGERSTAM, LG ;
FROSTELLKARLSSON, A ;
KARLSSON, R ;
PERSSON, B ;
RONNBERG, I .
JOURNAL OF CHROMATOGRAPHY, 1992, 597 (1-2) :397-410
[9]   IN-SITU QUARTZ-MICROBALANCE STUDY OF THE SELF-ASSEMBLY AND STABILITY OF ALIPHATIC THIOLS ON POLARIZED GOLD ELECTRODES [J].
FRUBOSE, C ;
DOBLHOFER, K .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1995, 91 (13) :1949-1953
[10]  
Gaspar S, 2001, ELECTROANAL, V13, P284, DOI 10.1002/1521-4109(200103)13:4<284::AID-ELAN284>3.0.CO