The influence of prepulse level on the 3p-3s XUV laser output from Ne-like ions of Zn, Cu and Ni

被引:28
作者
MacPhee, AG
Lewis, CLS
Warwick, PJ
Weaver, I
Jaegle, P
Carillon, A
Jamelot, G
Klisnick, A
Rus, B
Zeitoun, P
Nantel, M
Goedkindt, P
Sebban, S
Tallents, GJ
Demir, A
Holden, M
Krishnan, J
机构
[1] UNIV PARIS 11,LAB SPECT ATOM & ION,F-91405 ORSAY,FRANCE
[2] UNIV ESSEX,DEPT PHYS,COLCHESTER CO4 3SQ,ESSEX,ENGLAND
关键词
D O I
10.1016/S0030-4018(96)00435-X
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have studied the effect of prepulses in enhancing the efficiency of generating ASE beams in soft X-ray laser plasma amplifiers based on pumping Ne-like ions, Slab targets were irradiated with a weak prepulse followed by a main plasma heating pulse of nanosecond duration, Time-integrated; time and spectrally resolved and time and angularly resolved lasing emissions on the 3p-3s (J=0-1) XUV lasing lines of Ne-like Ni, Cu and Zn at wavelengths 232 Angstrom 221 Angstrom and 212 Angstrom respectively have been monitored. Measurements were made for pre-pulse/main-pulse intensity ratios from 10(-5)-10(-1) and for pump delay times of 2 ns and 4.5 ns. Zinc is shown to exhibit a peak in output intensity at similar to 2x10(-3) pre-pulse fraction for a 4.5 ns pump delay, with a main pulse pump intensity of similar to 1.3x10(13) W cm(-2) on a 20 mm target. The Zn lasing emission had a duration of similar to 240 ps and this was insensitive to prepulse fraction. The J=0-1 XUV laser output for nickel and copper increased monotonically with prepulse fraction, with copper targets showing least sensitivity to either prepulse level or prepulse to main pulse delay. Under the conditions of the study, the pre-pulse level was observed to haveno significant influence on the output intensity of the 3p-3s (J=2-1) lines of any of the elements investigated.
引用
收藏
页码:525 / 533
页数:9
相关论文
共 36 条
[21]   EFFECT OF WEAK PREPULSES ON COLLISIONAL X-RAY LASER PLASMAS [J].
NANTEL, M ;
KLISNICK, A ;
JAMELOT, G ;
HOLDEN, PB ;
JAEGLE, P ;
ZEITOUN, P ;
TALLENTS, G ;
MACPHEE, AG ;
LEWIS, CLS .
OPTICS LETTERS, 1995, 20 (22) :2333-2335
[22]  
NANTEL M, 1996, IN PRESS PHYS REV E
[23]   GAIN SCALING RELATIONSHIPS FOR NE-LIKE GE SLAB TARGETS [J].
NEELY, D ;
LEWIS, CLS ;
ONEILL, DM ;
UHOMOIBHI, JO ;
KEY, MH ;
ROSE, SJ ;
TALLENTS, GJ ;
RAMSDEN, SA .
OPTICS COMMUNICATIONS, 1992, 87 (5-6) :231-236
[24]  
Nickels PV, 1995, P SOC PHOTO-OPT INS, V2520, P373, DOI 10.1117/12.221656
[25]   NEARLY MONOCHROMATIC LASING AT 182-ANGSTROM IN NEON-LIKE SELENIUM [J].
NILSEN, J ;
MORENO, JC .
PHYSICAL REVIEW LETTERS, 1995, 74 (17) :3376-3379
[26]   USE OF THE PREPULSE TECHNIQUE TO ENHANCE THE WEAK 1,-2-NM LASER LINE IN NEON-LIKE SELENIUM [J].
NILSEN, J ;
MORENO, JC .
OPTICS LETTERS, 1994, 19 (15) :1137-1139
[27]   Relative merits of using curved targets and the prepulse technique to enhance the output of the neon-like germanium X-ray laser [J].
Nilsen, J ;
Li, YL ;
Lu, PX ;
Moreno, JC ;
Fill, EE .
OPTICS COMMUNICATIONS, 1996, 124 (3-4) :287-291
[28]   PREPULSE TECHNIQUE FOR PRODUCING LOW-Z NE-LIKE X-RAY LASERS [J].
NILSEN, J ;
MACGOWAN, BJ ;
DASILVA, LB ;
MORENO, JC .
PHYSICAL REVIEW A, 1993, 48 (06) :4682-4685
[29]   1ST OBSERVATION OF LASING AT 231-ANGSTROM IN NEON-LIKE NICKEL USING THE PREPULSE TECHNIQUE [J].
NILSEN, J ;
MORENO, JC ;
MACGOWAN, BJ ;
KOCH, JA .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1993, 57 (05) :309-311
[30]  
NILSEN J, 1993, P SOC PHOTO-OPT INS, V2012, P131