Value of radiography in diagnosing complications of cardioverter defibrillators implanted without thoracotomy in 437 patients

被引:15
作者
Gupta, A [1 ]
Zegel, HG [1 ]
Dravid, VS [1 ]
Nierenberg, SJ [1 ]
Freiman, DB [1 ]
机构
[1] UNIV PENN,PRESBYTERIAN MED CTR,DEPT CARDIOL,PHILADELPHIA,PA 19104
关键词
D O I
10.2214/ajr.168.1.8976930
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study evaluated the usefulness of radiography in assessing the frequency and cause of complications of nonthoracotomy-implanted cardioverter defibrillators. MATERIALS AND METHODS. Between May 1992 and December 1995, 437 consecutive patients at our institution underwent cardioverter defibrillator placement. Routine follow-up included external device testing at 6 weeks after placement and every 3 months thereafter. Chest radiographs were obtained immediately after placement, annually, and at the time of any suspected complication. Retrospective review of radiographs and medical charts was done for all patients with clinical complications. RESULTS. Forty-five complications (10%) were clinically diagnosed: lead or patch fracture in fifteen (33%) patients, electric lead dysfunction in eight (18%), infection in eight (18%), lead retraction in six (13%), patch fold in two (5%), hematoma in two (5%), and other complications in four (9%) patients. Eighteen complications (40%) were radiographically evident. Lead retraction, hematoma, patch fold, patch migration, and the twiddler syndrome were radiographically confirmed in 100% of cases. The average time for these complications to be detected was 68 days; 92% were detected within 23 days. Conversely, only four (27%) lead fractures, one (13%) electric lead dysfunction, and one (13%) infection were radiographically confirmed. These latter complications were discovered an average of 579 days after cardioverter defibrillator placement. CONCLUSION. Radiography plays a secondary role in the diagnosis of cardioverter defibrillator complications and is particularly limited beyond 1 month after placement. Radiographs may be helpful in the first month after placement because early complications are the most radiographically apparent.
引用
收藏
页码:105 / 108
页数:4
相关论文
共 10 条
[1]  
BAROLD SS, 1992, HEART DISEASE, P726
[2]  
BROOKS R, 1994, HURSTS HEART, P847
[3]   CARDIOVERTER-DEFIBRILLATOR SYSTEMS IMPLANTED WITHOUT THORACOTOMY - RADIOGRAPHIC FINDINGS [J].
CHMIELEWSKI, SR ;
ZEGEL, HG ;
GOTTLIEB, C ;
FREIMAN, DB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (05) :943-946
[4]   IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY - 15 YEARS EXPERIENCE AND FUTURE EXPECTATIONS [J].
COUMEL, P ;
PRYSTOWSKY, EN .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (03) :505-505
[5]   NONTHORACOTOMY LEAD IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - NORMAL RADIOGRAPHIC APPEARANCE [J].
DALY, BD ;
HUMMEL, JD ;
LANGBERG, J ;
STRICKBERGER, SA ;
KALBFLEISCH, S ;
MORADY, F ;
CASCADE, PN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (04) :749-752
[6]  
DAVIDSON T, 1994, HEART LUNG, V23, P205
[7]   MALFUNCTION OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS PLACED BY A NONTHORACOTOMY APPROACH - FREQUENCY OF MALFUNCTION AND VALUE OF CHEST RADIOGRAPHY IN DETERMINING CAUSE [J].
DRUCKER, EA ;
BROOKS, R ;
GARAN, H ;
SWEENEY, MO ;
RUSHKIN, JM ;
MCGOVERN, BA ;
MILLER, SW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :275-279
[8]  
EAGER G, 1994, AJR, V162, P25
[9]   THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EFFICACY, COMPLICATIONS, AND DEVICE FAILURES [J].
MARCHLINSKI, FE ;
FLORES, BT ;
BUXTON, AE ;
HARGROVE, WC ;
ADDONIZIO, VP ;
STEPHENSON, LW ;
HARKEN, AH ;
DOHERTY, JU ;
GROGAN, EW ;
JOSEPHSON, ME .
ANNALS OF INTERNAL MEDICINE, 1986, 104 (04) :481-488
[10]   IMPLANTATION OF A CARDIOVERTER DEFIBRILLATOR WITHOUT THORACOTOMY USING A TRIPLE ELECTRODE SYSTEM [J].
SAKSENA, S ;
PARSONNET, V .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 259 (01) :69-72