Selective and sensitive procedures for the determination of ammonium in river water and diluted urine were developed by using flow injection analysis equipment. The methods are based on the derivatization of ammonia with o-phthaldehyde (OPA) and thioglycolate under alkaline conditions. The formed isoindole derivative is detected fluorimetrically at an excitation wavelength of 415 nm and an emission wavelength of 485 nm. The derivatization only takes 15 to 20 s at room temperature to achieve the maximum sensitivity. The optimized OPA reagent shows a surprisingly high selectivity for ammonium in the presence of many primary amines. With respect to the analysis of turbid and fluorescent sample solutions the selectivity can be improved by separating the ammonia through a microporous membrane from the OPA reagent. Without this separation step ammonia can be detected in the range between 0.05 and 100 mu M with excellent linearity. After the insertion of an optimized membrane separation cell ammonia can be determined in the linear range between 0.2 mu M and 20 mM.
引用
收藏
页码:825 / 829
页数:5
相关论文
共 40 条
  • [1] FLUOROMETRIC-DETERMINATION OF UREA BY FLOW-INJECTION ANALYSIS
    ABDELLATIF, MS
    GUILBAULT, GG
    [J]. JOURNAL OF BIOTECHNOLOGY, 1990, 14 (01) : 53 - 61
  • [2] [Anonymous], 1986, ENV POL SUS DEV
  • [3] CONTINUOUS-FLOW FLUOROMETRIC-DETERMINATION OF AMMONIA IN WATER
    AOKI, T
    UEMURA, S
    MUNEMORI, M
    [J]. ANALYTICAL CHEMISTRY, 1983, 55 (09) : 1620 - 1622
  • [4] Integrated automatic determination of nitrate, ammonium and organic carbon in soil samples
    Ballesteros, E
    Rios, A
    Valcarcel, M
    [J]. ANALYST, 1997, 122 (04) : 309 - 313
  • [5] ENZYMATIC DETERMINATION OF AMMONIA IN FOOD BY FLOW-INJECTION
    CANALEGUTIERREZ, L
    MAQUIEIRA, A
    PUCHADES, R
    [J]. ANALYST, 1990, 115 (09) : 1243 - 1246
  • [6] EVALUATION OF FLOW-INJECTION METHODS FOR AMMONIUM DETERMINATION IN WASTE-WATER SAMPLES
    CERDA, A
    OMS, MT
    FORTEZA, R
    CERDA, V
    [J]. ANALYTICA CHIMICA ACTA, 1995, 311 (02) : 165 - 173
  • [7] AN AUTOMATED SPECTROPHOTOMETRIC FIELD-MONITOR FOR WATER-QUALITY PARAMETERS - DETERMINATION OF AMMONIA
    CLINCH, JR
    WORSFOLD, PJ
    SWEETING, FW
    [J]. ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) : 401 - 407
  • [8] POTENTIOMETRIC AND CONDUCTOMETRIC DETERMINATION OF AMMONIUM BY GAS-DIFFUSION FLOW-INJECTION ANALYSIS
    FRENZEL, W
    LIU, CY
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (4-5): : 276 - 280
  • [9] GENFA Z, 1989, ENVIRON SCI TECHNOL, V23, P1467, DOI 10.1021/es00070a003
  • [10] GENFA Z, 1989, Analytical Chemistry, V61, P408, DOI 10.1021/ac00180a006