Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve

被引:210
作者
Branner, A
Stein, RB
Fernandez, E
Aoyagi, Y
Normann, RA
机构
[1] Univ Utah, Ctr Neural Informat, Dept Bioengn, Salt Lake City, UT 84112 USA
[2] Univ Alberta, Ctr Neurosci, Edmonton, AB T6G 2S2, Canada
[3] Univ Miguel Hernandez, Dept Histol, Fac Med, Alicante 03550, Spain
[4] Univ Miguel Hernandez, Inst Bioengn, Fac Med, Alicante 03550, Spain
[5] Univ Alberta, Ctr Neurosci, Edmonton, AB T6G 2S2, Canada
[6] Univ Utah, Ctr Neural Interfaces, Dept Bioengn, Salt Lake City, UT 84112 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
functional neuromuscular stimulation (FNS); implantable electrodes; neuroprosthesis; peripheral nerve;
D O I
10.1109/TBME.2003.820321
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We studied the consequences of long-term implantation of a penetrating microelectrode array in peripheral nerve over the time course of 4-6 mo. Electrode arrays without lead wires were implanted to test the ability of different containment systems to protect the array and nerve during contractions of surrounding muscles. Treadmill walking was monitored and the animals showed no functional deficits as a result of implantation. In a different set of experiments, electrodes with lead wires were implanted for up to 7 mo and the animals were tested at 2-4 week intervals at which time stimulation thresholds and recorded sensory activity were monitored for every electrode. It was shown that surgical technique highly affected the long-term stimulation results. Results between measurement sessions were compared, and in the best case, the stimulation properties stabilized in 80% of the electrodes over the course of the experiment (162 days). The recorded sensory signals, however, were not stable over time. A histological analysis performed on all implanted tissues indicated that the morphology and fiber density of the nerve around the electrodes were normal.
引用
收藏
页码:146 / 157
页数:12
相关论文
共 32 条
[1]   CONSIDERATIONS FOR SAFETY WITH CHRONICALLY IMPLANTED NERVE ELECTRODES [J].
AGNEW, WF ;
MCCREERY, DB .
EPILEPSIA, 1990, 31 :S27-S32
[2]  
AOYAGI Y, 2001, SOC NEUR ABSTR, V27
[3]   A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats [J].
Branner, A ;
Normann, RA .
BRAIN RESEARCH BULLETIN, 2000, 51 (04) :293-306
[4]   Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes [J].
Branner, A ;
Stein, RB ;
Normann, RA .
JOURNAL OF NEUROPHYSIOLOGY, 2001, 85 (04) :1585-1594
[5]   Bridging areas of injury in the spinal cord [J].
Bunge, MB .
NEUROSCIENTIST, 2001, 7 (04) :325-339
[6]   Long-term biocompatibility of a miniature stimulator implanted in feline hind limb muscles [J].
Cameron, T ;
Liinamaa, TL ;
Loeb, GE ;
Richmond, FJR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (08) :1024-1035
[7]   Selectivity of multiple-contact nerve cuff electrodes: A simulation analysis [J].
Choi, AQ ;
Cavanaugh, JK ;
Durand, DM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (02) :165-172
[8]   New easy to install nerve cuff electrode using shape memory alloy armature [J].
Crampon, MA ;
Sawan, M ;
Brailovski, V ;
Trochu, F .
ARTIFICIAL ORGANS, 1999, 23 (05) :392-395
[9]   A USEFUL PROGRAM IN BASIC FOR AXONAL MORPHOMETRY WITH INTRODUCTION OF NEW CYTOSKELETAL PARAMETERS [J].
FERNANDEZ, E ;
CUENCA, N ;
DEJUAN, J .
JOURNAL OF NEUROSCIENCE METHODS, 1991, 39 (03) :271-289
[10]  
Grill W M, 1998, IEEE Trans Rehabil Eng, V6, P364, DOI 10.1109/86.736150