Temperature, eluent flow-rate and column effects on the retention and quantitation properties of phenylthiocarbamyl derivatives of amino acids in reversed-phase high-performance liquid chromatography

被引:32
作者
Vasanits, A [1 ]
Molnár-Perl, I [1 ]
机构
[1] Eotvos Lorand Univ, Inst Inorgan & Analyt Chem, H-1518 Budapest 112, Hungary
关键词
apples; food analysis; fruits; amino acids;
D O I
10.1016/S0021-9673(98)00977-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The separation and identification possibilities of 27 PTC-amino acids (with particular attention to those present in apples in free forms), are reported on seven RP columns such as, Nucleosil, 3 and 5 mu m: 150(+20 guard) X 4.0 mm; Gromsil 3 mu m; 150(+10 guard) X 4.0 mm; Hypersil 5 mu m: 130(+20 guard) X 4.0 mm, 150(+20 guard) X 4.0 mm and 200(+20 guard) X 4.0 mm, as well as, Hypersil 3 mu m: 150(+20 guard) X 4.0 mm: a UV range photodiode array (PDA) detection was employed. Optimization studies carried out in model solutions, as a function of the temperature (30-55 degrees C) and flow-rate (0.8-2.5 mi/min) of eluents proved that optimum resolutions are associated with the highest flow-rate applicable, (remaining on the safe side with a column pressure of <3500 p.s.i., 1 p.s.i. = 6894.76 Pa), in the temperature range of 30-50 degrees C. Twenty-seven amino acids, characteristic in apples in free forms, have been separated and determined on all seven columns, performing the same gradient program, (the main component asparagine, present in overwhelming excess, and the minor constituents glutamine, beta-alanine, gamma-aminobutyric acid, homoserine, homoarginine and 1-aminocyclopropane-1-carboxylic acid). Optimum conditions, at 2.1 ml/min, at 50 degrees C, with 40 min run time, including equilibration, have been obtained with the Hypersil, 150(+20 guard) X 4 mm column, performing elutions. Responses of the corresponding amino acids proved to be independent of the column used; reproducibility in the concentration range of 15-1500 pmol was <4.0% R.S.D. (relative standard deviation). Detailed study of the PDA spectra revealed that in addition to the identification/peak purity possibilities further characteristics can be obtained taking advantage of the difference in maximum values and of those of their special ratio values, respectively. The utility of the protocol was shown in the quantitation of the free amino acid content of three apple varieties. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:109 / 122
页数:14
相关论文
共 38 条
[1]   DEPROTEINIZATION TECHNIQUES FOR HPLC AMINO-ACID-ANALYSIS IN FRESH PORK MUSCLE AND DRY-CURED HAM [J].
ARISTOY, MC ;
TOLDRA, F .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1991, 39 (10) :1792-1795
[2]  
Bielig H. J., 1982, Fluessiges Obst, V49, P50
[3]  
Bielig H.-J., 1972, Chemie Mikrobiologie Technologie der Lebensmittel, V1, P183
[4]   CHROMATOGRAPHIC DETERMINATION OF D-AMINO ACIDS AS NATIVE CONSTITUENTS OF VEGETABLES AND FRUITS [J].
BRUCKNER, H ;
WESTHAUSER, T .
CHROMATOGRAPHIA, 1994, 39 (7-8) :419-426
[5]  
CALLUL M, 1991, CHROMATOGRAPHIA, V31, P272
[6]  
CHAYTOR JP, 1986, J SCI FOOD AGR, V37, P1019, DOI 10.1002/jsfa.2740371010
[7]   AN LCEC METHOD FOR THE ANALYSIS OF SYNTHETIC AMINO-ACIDS IN FRUIT JUICES [J].
DYREMARK, A ;
ERICSSON, M .
CHROMATOGRAPHIA, 1990, 29 (1-2) :51-53
[8]   STANDARDIZATION OF CATION-EXCHANGE CLEANUP PRIOR TO GAS-CHROMATOGRAPHY OF AMINO-ACIDS [J].
FABIAN, V ;
MORVAI, M ;
PINTERSZAKACS, M ;
MOLNARPERL, I .
JOURNAL OF CHROMATOGRAPHY, 1991, 553 (1-2) :87-92
[9]   REVERSED-PHASE CHROMATOGRAPHY OF PHENYLTHIOCARBAMYL AMINO-ACID DERIVATIVES OF PHYSIOLOGICAL AMINO-ACIDS - AN EVALUATION AND A COMPARISON WITH ANALYSIS BY ION-EXCHANGE CHROMATOGRAPHY [J].
FESTE, AS .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 574 (01) :23-34
[10]   APPLICATION OF AMINO-ACID-ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHENYL ISOTHIOCYANATE DERIVATIZATION TO THE RAPID-DETERMINATION OF FREE AMINO-ACIDS IN BIOLOGICAL SAMPLES [J].
FIERABRACCI, V ;
MASIELLO, P ;
NOVELLI, M ;
BERGAMINI, E .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (02) :285-291