Comparing methods of measurement

被引:245
作者
Ludbrook, J
机构
[1] Cardiovascular Research Laboratory, Univ. of Melbourne Dept. of Surgery, Royal Melbourne Hospital, Parkville, Vic.
[2] Univ. of Melbourne Dept. of Surgery, Royal Melbourne Hospital, Parkville
关键词
correlation; Deming's method; differences; least products; least squares; model I regression; model II regression; random error; residuals; systematic bias;
D O I
10.1111/j.1440-1681.1997.tb01807.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
1, The purpose of comparing two methods of measurement of a continuous biological variable is to uncover systematic differences not to point to similarities. 2, There are two potential sources of systematic disagreement between methods of measurement: fixed and proportional bias. 3. Fired bias means that one method gives values that are higher (or lower) than those from the other by a constant amount. Proportional bias means that one method gives values that are higher (or lower) than those from the other by an amount that is proportional to the level of the measured variable. 4, It must be assumed that measurements made by either method are attended by random error: in making measurements and from biological variation. 5. Investigators often use the Pearson product-moment correlation coefficient (r) to compare methods of measurement. This cannot detect systematic biases, only random error. 6. Investigators sometimes use least squares (Model I) regression analysis to calibrate one method of measurement against another, In this technique, the sum of the squares of the vertical deviations of y values from the line is minimized, This approach is invalid, because both y and x values are attended by random error. 7. Model II regression analysis caters for cases in which random error is attached to both dependent and independent variables. Comparing methods of measurement is just such a case. 8. Least products regression is the reviewer's preferred technique for analysing the Model II case. In this, the sum of the products of the vertical and horizontal deviations of the x,y values from the line is minimized. 9. Least products regression analysis is suitable for calibrating one method against another, It is also a sensitive technique for detecting and distinguishing fired and proportional bias between methods. 10. An alternative approach is to examine the differences between methods in order to detect bias. This has been recommended to clinical scientists and has been adopted by many. 11. It is the reviewer's opinion that the least products regression technique is to be preferred to that of examining differences, because the former distinguishes between fixed and proportional bias, whereas the latter does not.
引用
收藏
页码:193 / 203
页数:11
相关论文
共 34 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
[Anonymous], 1981, Statistical Tables
[3]   ARE THERE 2 REGRESSIONS [J].
BERKSON, J .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1950, 45 (250) :164-180
[4]  
Berry W.D., 1993, Understanding regression assumptions
[5]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]  
BOX GEP, 1978, STATISTICS EXPT
[8]   FITTING STRAIGHT LINES TO EXPERIMENTAL-DATA [J].
BRACE, RA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 233 (03) :R94-R99
[9]   THE ASSESSMENT OF METHODS OF MEASUREMENT [J].
CHINN, S .
STATISTICS IN MEDICINE, 1990, 9 (04) :351-362
[10]   FINGER SYSTOLIC PRESSURE - ITS USE IN SCREENING FOR HYPERTENSION AND MONITORING [J].
CLOSE, A ;
HAMILTON, G ;
MURISS, S .
BRITISH MEDICAL JOURNAL, 1986, 293 (6550) :775-778