PULSE PRESSURE VARIATION: WHERE ARE WE TODAY?

被引:53
作者
Cannesson, Maxime [1 ]
Aboy, Mateo [2 ]
Hofer, Christoph K. [3 ]
Rehman, Mohamed [4 ]
机构
[1] Univ Calif Irvine, Dept Anesthesiol & Perioperat Care, Orange, CA 92868 USA
[2] Oregon Inst Technol, Dept Elect Engn & Renewable Energy, Portland, OR USA
[3] Triemli City Hosp Zurich, Inst Anesthesiol & Intens Care Med, Zurich, Switzerland
[4] Childrens Hosp Philadelphia, Dept Anesthesiol & Crit Care Med, Philadelphia, PA 19104 USA
关键词
Fluid responsiveness; fluid optimization; cardiac output; outcome; monitoring; arterial pressure; PREDICT FLUID RESPONSIVENESS; WAVE-FORM AMPLITUDE; PULMONARY-ARTERY CATHETER; PLETHYSMOGRAPHIC DYNAMIC INDEXES; MECHANICALLY VENTILATED PATIENTS; RESPIRATORY-DISTRESS-SYNDROME; ACUTE CIRCULATORY FAILURE; PLETH VARIABILITY INDEX; CRITICALLY-ILL PATIENTS; CARDIAC-OUTPUT;
D O I
10.1007/s10877-010-9229-1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In the present review we will describe and discuss the physiological and technological background necessary in understanding the dynamic parameters of fluid responsiveness and how they relate to recent softwares and algorithms' applications. We will also discuss the potential clinical applications of these parameters in the management of patients under general anesthesia and mechanical ventilation along with the potential improvements in the computational algorithms.
引用
收藏
页码:45 / 56
页数:12
相关论文
共 107 条
[1]   An automatic beat detection algorithm for pressure signals [J].
Aboy, M ;
McNames, J ;
Thong, T ;
Tsunami, D ;
Ellenby, MS ;
Goldstein, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (10) :1662-1670
[2]   A novel algorithm to estimate the pulse pressure variation index ΔPP [J].
Aboy, M ;
McNames, J ;
Thong, T ;
Phillips, CR ;
Ellenby, MS ;
Goldstein, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (12) :2198-2203
[3]   An Enhanced Automatic Algorithm for Estimation of Respiratory Variations in Arterial Pulse Pressure During Regions of Abrupt Hemodynamic Changes [J].
Aboy, Mateo ;
Crespo, Cristina ;
Austin, Daniel .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (10) :2537-2545
[4]   Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care [J].
Bendjelid, K ;
Romand, JA .
INTENSIVE CARE MEDICINE, 2003, 29 (03) :352-360
[5]   Continuous cardiac output monitoring after cardiopulmonary bypass:: a comparison with bolus thermodilution measurement [J].
Bendjelid, K ;
Schütz, N ;
Suter, PM ;
Romand, JA .
INTENSIVE CARE MEDICINE, 2006, 32 (06) :919-922
[6]  
BIAIS M, 2009, BRIT J ANAESTH, V101, P735
[7]   RETRACTED: Volume replacement strategies on intensive care units: results from a postal survey (Retracted Article) [J].
Boldt, J ;
Lenz, M ;
Kumle, B ;
Papsdorf, M .
INTENSIVE CARE MEDICINE, 1998, 24 (02) :147-151
[8]   Impact of perioperative haemodynamic monitoring on cardiac morbidity after major vascular surgery in low risk patients. A randomised pilot trial [J].
Bonazzi, M ;
Gentile, F ;
Biasi, GM ;
Migliavacca, S ;
Esposti, D ;
Cipolla, M ;
Marsicano, M ;
Prampolini, F ;
Ornaghi, M ;
Sternjakob, S ;
Tshomba, Y .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2002, 23 (05) :445-451
[9]   A RANDOMIZED CLINICAL-TRIAL OF THE EFFECT OF DELIBERATE PERIOPERATIVE INCREASE OF OXYGEN DELIVERY ON MORTALITY IN HIGH-RISK SURGICAL PATIENTS [J].
BOYD, O ;
GROUNDS, RM ;
BENNETT, ED .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 270 (22) :2699-2707
[10]  
BUETTNER M, 2008, BR J ANAESTH