An Enhanced Automatic Algorithm for Estimation of Respiratory Variations in Arterial Pulse Pressure During Regions of Abrupt Hemodynamic Changes

被引:12
作者
Aboy, Mateo [1 ,2 ]
Crespo, Cristina [1 ,3 ]
Austin, Daniel [1 ,4 ,5 ]
机构
[1] Oregon Inst Technol, Dept Elect Engn, Beaverton, OR 97006 USA
[2] Univ London, London WC1E 7HU, England
[3] Univ Vigo, ETSIT Vigo, Sch Telecommun Engineers, Vigo 36310, Spain
[4] Portland State Univ, Portland, OR 97207 USA
[5] Oregon Hlth & Sci Univ, Biomed Engn Div, Portland, OR 97239 USA
关键词
Fluid responsiveness; hemodynamic monitoring; pulse contour cardiac output (PICCO); pulse contour analysis; pulse-pressure-variation (PPV) index (PPV); stroke-volume-variation index (SSV); ACUTE CIRCULATORY FAILURE; CARDIAC-OUTPUT SYSTEM; FLUID RESPONSIVENESS; STROKE VOLUME; THERMODILUTION; PREDICTION; MONITOR; SURGERY; MODEL; INDEX;
D O I
10.1109/TBME.2009.2024761
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe an improved automatic algorithm to estimate the pulse-pressure-variation (PPV) index from arterial blood pressure (ABP) signals. This enhanced algorithm enables for PPV estimation during periods of abrupt hemodynamic changes. Numerous studies have shown PPV to be one of most specific and sensitive predictors of fluid responsiveness in mechanically ventilated patients. The algorithm uses a beat detection algorithm to perform beat segmentation, kernel smoothers for envelope detection, and a suboptimal Kalman filter for PPV estimation and artifact removal. In this paper, we provide a detailed description of the algorithm and assess its performance on over 40 h of ABP signals obtained from 18 mechanically ventilated crossbred Yorkshire swine. The subjects underwent grade V liver injury after splenectomy, while receiving mechanical ventilation, and general anesthesia with isoflurane. All subjects in the database underwent a period of abrupt hemodynamic change after an induced grade V liver injury involving severe blood loss resulting in hemorrhagic shock, followed by fluid resuscitation with either 0.9% normal saline or lactated ringers solutions. Trained experts manually calculated PPV at five time instances during the period of abrupt hemodynamic changes. We report validation results comparing the proposed algorithm against a commercial system (pulse contour cardiac output, PICCO) with continuous PPV monitoring capabilities. Both systems were assessed during periods of abrupt hemodynamic changes against the "gold-standard" PPV, calculated and manually annotated by experts. Our results indicate that the proposed algorithm performs considerably better than the PICCO system during regions of abrupt hemodynamic changes.
引用
收藏
页码:2537 / 2545
页数:9
相关论文
共 31 条
[1]   An automatic beat detection algorithm for pressure signals [J].
Aboy, M ;
McNames, J ;
Thong, T ;
Tsunami, D ;
Ellenby, MS ;
Goldstein, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (10) :1662-1670
[2]   A novel algorithm to estimate the pulse pressure variation index ΔPP [J].
Aboy, M ;
McNames, J ;
Thong, T ;
Phillips, CR ;
Ellenby, MS ;
Goldstein, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (12) :2198-2203
[3]   Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model [J].
Bajorat, J ;
Hofmockel, R ;
Vagts, DA ;
Janda, M ;
Pohl, B ;
Beck, C ;
Noeldge-Schomburg, G .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (01) :23-30
[4]  
Berkenstadt H, 2001, ANESTH ANALG, V92, P984
[5]   Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre [J].
Cannesson, M. ;
Desebbe, O. ;
Rosamel, P. ;
Delannoy, B. ;
Robin, J. ;
Bastien, O. ;
Lehot, J. -J. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) :200-206
[6]  
CANNESSON M, 2008, ANN FR ANESTH RE OCT
[7]   The ability of a novel algorithm for automatic estimation of the respiratory variations, in arterial pulse pressure to monitor fluid responsiveness in the operating room [J].
Cannesson, Maxime ;
Slieker, Juliette ;
Desebbe, Olivier ;
Bauer, Christian ;
Chiari, Pascal ;
Henaine, Roland ;
Lehot, Jean-Jacques .
ANESTHESIA AND ANALGESIA, 2008, 106 (04) :1195-1200
[8]   Time course and prognostic value of plasma B-type natriuretic peptide concentration in neonates undergoing the arterial switch operation [J].
Cannesson, Maxime ;
Bionda, Clara ;
Gostoli, Bruno ;
Raisky, Olivier ;
di Filippo, Sylvie ;
Bompard, Dominique ;
Verdrinne, Catherine ;
Rousson, Robert ;
Ninet, Jean ;
Neidecker, Jean ;
Lehot, Jean-Jacques .
ANESTHESIA AND ANALGESIA, 2007, 104 (05) :1059-1065
[9]   Estimation of left ventricular systolic function by single transpulmonary thermodilution [J].
Combes, A ;
Berneau, JB ;
Luyt, CE ;
Trouillet, JL .
INTENSIVE CARE MEDICINE, 2004, 30 (07) :1377-1383
[10]  
Della Rocca G, 2003, CAN J ANAESTH, V50, P707