Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model

被引:73
作者
Bajorat, J [1 ]
Hofmockel, R [1 ]
Vagts, DA [1 ]
Janda, M [1 ]
Pohl, B [1 ]
Beck, C [1 ]
Noeldge-Schomburg, G [1 ]
机构
[1] Univ Rostock, Sch Med, Dept Anaesthesiol & Intens Care Med, D-18057 Rostock, Germany
关键词
cardiac output; measurement; comparisons; fick principle; oesophageal Doppler; partial carbon dioxide rebreathing; monitoring physiologic; catheterization Swan Ganz;
D O I
10.1017/S0265021505001717
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: Despite the introduction of various less-invasive concepts of cardiac output measurement, pulmonary arterial thermodilution is still the most common measurement technique. Methods: This prospective controlled study was designed to compare different methods of cardiac output measurement simultaneously. Pulmonary arterial thermodilution, transpulmonary thermodilution (PiCCO (TM)), trans-oesophageal echo-Doppler probe (HemoSonic (TM)) and partial carbon dioxide rebreathing technique (NICO (TM) monitor) were evaluated against a peri-aortic transit-time flow-probe as reference method in a clinically relevant animal model. After approval from the Local Ethics Committee on Animal Research, the investigations were conducted in nine anesthetized domestic pigs. Systemic haemodynamics were modulated systematically by the application of catecholamines, caval occlusion and exsanguination. Statistical analysis was performed with Bland-Altman and linear regression. Results: A total of 366 paired cardiac output measurements were carried out at a reference cardiac output between 0.5 and 7 L min(-1). The correlation coefficients for pulmonary arterial and transpulmonary thermodilution against reference were 0.93 and 0.95, for trans-oesophageal Doppler and partial rebreathing technique 0.84 and 0.77. Pulmonary arterial thermodilution and transpulmonary thermodilution showed comparable bias and limits of agreement. Where HemoSonic (TM) showed an overestimation of cardiac output at a higher precision, NICO (TM) overestimated low and underestimated higher cardiac output values. Conclusions: Our data suggest that pulmonary arterial thermodilution and PiCCO (TM) may be interchangeably used for cardiac output measurement even under acute haemodynamic changes. The method described by Bland and Altman demonstrated an overestimation of cardiac output for both thermodilution methods. HemoSonic (TM) and NICO (TM) offer non-invasive alternatives and complementary monitoring tools in numerous clinical situations. Trend monitoring and haemodynamic optimizing can be applied sufficiently, when absolute measures are judged critically in a clinical context. The use of the NICO (TM) system seems to be limited during acute circulatory changes.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 19 条
[1]   Cardiac output measurements during cross-clamping of the descending thoracic aorta in pigs -: A comparison between transit-time ultrasound, thermodilution and pulsed Doppler ultrasound [J].
Aadahl, P ;
Aakhus, S ;
Sæther, OD ;
Stomholm, T ;
Myhre, HO .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2000, 44 (02) :180-185
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Noninvasive cardiac output monitoring by aortic blood flow determination:: Evaluation of the Sometec Dynemo-3000 system [J].
Cariou, A ;
Monchi, M ;
Joly, LM ;
Bellenfant, F ;
Claessens, YE ;
Thébert, D ;
Brunet, F ;
Dhainaut, JF .
CRITICAL CARE MEDICINE, 1998, 26 (12) :2066-2072
[4]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[5]   Is it time to pull the pulmonary artery catheter? [J].
Dalen, JE ;
Bone, RC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :916-918
[6]   Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery [J].
Gan, TJ ;
Soppitt, A ;
Maroof, M ;
El-Moalem, H ;
Robertson, KM ;
Moretti, E ;
Dwane, P ;
Glass, PSA .
ANESTHESIOLOGY, 2002, 97 (04) :820-826
[7]   SEMINAR ON CLINICAL APPLICATION OF TECHNIQUES TO MEASURE BLOOD-FLOW IN MAN .2. MEASUREMENT OF BLOOD-FLOW BY THERMODILUTION [J].
GANZ, W ;
SWAN, HJC .
AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (02) :241-+
[8]   MIDCAB operations with the Octopus-system®:: Continuous cardiac output and afterload measurement by pulse-contour-analysis [J].
Gödje, O ;
Thiel, C ;
Reichenspurner, H ;
Schmitz, C ;
Kilger, E ;
Götz, A ;
Reichart, B .
CRITICAL CARE MEDICINE, 1999, 27 (01) :A112-A112
[9]   Continuous oesophageal aortic blood flow echo-Doppler measurement during general anaesthesia in infants [J].
Gueugniaud, PY ;
Muchada, R ;
Moussa, M ;
Haro, D ;
Petit, P .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1997, 44 (07) :745-750
[10]  
HARTMAN JC, 1994, J PHARMACOL TOXICOL, V31, P153