Continuous oesophageal aortic blood flow echo-Doppler measurement during general anaesthesia in infants

被引:12
作者
Gueugniaud, PY [1 ]
Muchada, R [1 ]
Moussa, M [1 ]
Haro, D [1 ]
Petit, P [1 ]
机构
[1] UNIV LYON 1,F-69365 LYON,FRANCE
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1997年 / 44卷 / 07期
关键词
D O I
10.1007/BF03013390
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose: Invasive haemodynamic monitoring during general anaesthesia in infants is usually limited to very high risk operations, such as cardiac surgery. Nevertheless, different surgical procedures and/or anaesthetic techniques justify additional monitoring for children, as for adults. The aim of this preliminary study was to evaluate the feasibility of using a new echo-Doppler device (Dynemo 3000(R)) capable of measuring continuous aortic blood flow during general anaesthesia in infants. Methods: Aortic blood flow (ABF) was measured with a small oesophageal probe designed for newborns and infants. The aortic flowmeter was connected with satellite devices to visualise the haemodynamic profile which included ABF; pre-ejection period (PEPi), left ventricular ejection time (LVETi), mean arterial pressure, heart rate, stroke volume and systemic vascular resistance. Twelve infants, aged 8-26 mo, undergoing surgery under general anaesthesia were successively included in the evaluation of this device. Isoflurane (1% end-expired concentration) was introduced to maintain anaesthesia after induction with halothane, midazolam, fentanyl and atracurium. Results: Correct positioning of the probe was easily obtained in all cases and the recording quality was excellent, whatever the operative position. Recordings of haemodynamic data showed some myocardial depression from isoflurane: decreased ABF (indexed to body surface area) and lengthened PEP/LVET (2.24 +/- 0.53 L.min(-1).m(-2) and 0.32 +/- 0.05 respectively, before introduction of isoflurane and 1.71 +/- 0.53 L.min(-1).m(-2) (P = 0.027) and 0.39 +/- 0.06 (P = 0.007) with isoflurane). Conclusion: These preliminary results suggest that this continuous ABF echo-Doppler device may be valuable for peri anaesthetic monitoring in infants.
引用
收藏
页码:745 / 750
页数:6
相关论文
共 37 条
[1]   CONTINUOUS CARDIAC-OUTPUT DETERMINATION USING TRANS-TRACHEAL DOPPLER - INITIAL RESULTS IN HUMANS [J].
ABRAMS, JH ;
WEBER, RE ;
HOLMEN, KD .
ANESTHESIOLOGY, 1989, 71 (01) :11-15
[2]   NON-INVASIVE PULSED DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN NEONATES AND CHILDREN [J].
ALVERSON, DC ;
ELDRIDGE, M ;
DILLON, T ;
YABEK, SM ;
BERMAN, W .
JOURNAL OF PEDIATRICS, 1982, 101 (01) :46-50
[3]   SYSTOLIC-TIME INTERVALS [J].
BOUDOULAS, H .
EUROPEAN HEART JOURNAL, 1990, 11 :93-104
[4]  
BRUNEL D, 1991, PRESSE MED, V20, P1665
[5]  
CATHIGNOL D, 7814494 INSERM
[6]  
DAIGLE RE, 1975, J APPL PHYSIOL, V38, P1153, DOI 10.1152/jappl.1975.38.6.1153
[7]   THE USE OF BALLOON-TIPPED PULMONARY-ARTERY CATHETERS IN CHILDREN UNDERGOING CARDIAC-SURGERY [J].
DAMEN, J ;
WEVER, JEAT .
INTENSIVE CARE MEDICINE, 1987, 13 (04) :266-272
[8]   COMPARISON OF CARDIAC-OUTPUT MEASUREMENT TECHNIQUES - THERMODILUTION, DOPPLER, CO2-REBREATHING AND THE DIRECT FICK METHOD [J].
ESPERSEN, K ;
JENSEN, EW ;
ROSENBORG, D ;
THOMSEN, JK ;
ELIASEN, K ;
OLSEN, NV ;
KANSTRUP, IL .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 (02) :245-251
[9]   PEDIATRIC BIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY - PRELIMINARY EXPERIENCE [J].
GENTLES, TL ;
ROSENFELD, HM ;
SANDERS, SP ;
LAUSSEN, PC ;
BURKE, RP ;
VANDERVELDE, ME .
AMERICAN HEART JOURNAL, 1994, 128 (06) :1225-1233
[10]   DIAGNOSIS OF CIRCULATORY ARREST FROM CARBON-DIOXIDE EMBOLISM WITH AORTIC BLOOD-FLOW AND CAPNOGRAM MONITORING DURING LAPAROSCOPIC CHOLECYSTECTOMY [J].
GUEUGNIAUD, PY ;
BERTINMAGHIT, M ;
PETIT, P ;
MUCHADA, R .
ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1995, 14 (05) :417-420