Continuous oesophageal aortic blood flow echo-Doppler measurement during general anaesthesia in infants

被引:12
作者
Gueugniaud, PY [1 ]
Muchada, R [1 ]
Moussa, M [1 ]
Haro, D [1 ]
Petit, P [1 ]
机构
[1] UNIV LYON 1,F-69365 LYON,FRANCE
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1997年 / 44卷 / 07期
关键词
D O I
10.1007/BF03013390
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose: Invasive haemodynamic monitoring during general anaesthesia in infants is usually limited to very high risk operations, such as cardiac surgery. Nevertheless, different surgical procedures and/or anaesthetic techniques justify additional monitoring for children, as for adults. The aim of this preliminary study was to evaluate the feasibility of using a new echo-Doppler device (Dynemo 3000(R)) capable of measuring continuous aortic blood flow during general anaesthesia in infants. Methods: Aortic blood flow (ABF) was measured with a small oesophageal probe designed for newborns and infants. The aortic flowmeter was connected with satellite devices to visualise the haemodynamic profile which included ABF; pre-ejection period (PEPi), left ventricular ejection time (LVETi), mean arterial pressure, heart rate, stroke volume and systemic vascular resistance. Twelve infants, aged 8-26 mo, undergoing surgery under general anaesthesia were successively included in the evaluation of this device. Isoflurane (1% end-expired concentration) was introduced to maintain anaesthesia after induction with halothane, midazolam, fentanyl and atracurium. Results: Correct positioning of the probe was easily obtained in all cases and the recording quality was excellent, whatever the operative position. Recordings of haemodynamic data showed some myocardial depression from isoflurane: decreased ABF (indexed to body surface area) and lengthened PEP/LVET (2.24 +/- 0.53 L.min(-1).m(-2) and 0.32 +/- 0.05 respectively, before introduction of isoflurane and 1.71 +/- 0.53 L.min(-1).m(-2) (P = 0.027) and 0.39 +/- 0.06 (P = 0.007) with isoflurane). Conclusion: These preliminary results suggest that this continuous ABF echo-Doppler device may be valuable for peri anaesthetic monitoring in infants.
引用
收藏
页码:745 / 750
页数:6
相关论文
共 37 条
[11]   NONINVASIVE CONTINUOUS HEMODYNAMIC AND PETCO(2) MONITORING DURING PEROPERATIVE CARDIAC-ARREST [J].
GUEUGNIAUD, PY ;
MUCHADA, R ;
BERTINMAGHIT, M ;
GRIFFITH, N ;
PETIT, P .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (10) :910-913
[12]  
GUEUGNIAUD PY, 1995, ANESTHESIOLOGY, V83, pA1160
[13]  
GUEUGNIAUD PY, 1993, REAN URG, V2, P533
[14]  
GUEUGNIAUD PY, 1995, ANN FR ANESTH, V14, pR32
[15]   USEFULNESS OF BIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN NEONATES, INFANTS AND CHILDREN WITH CONGENITAL HEART-DISEASE [J].
LAM, J ;
NEIROTTI, RA ;
LUBBERS, WJ ;
NAEFF, MSJ ;
BLOMMUILWIJK, CM ;
SCHULLER, JL ;
MACARTNEY, FJ ;
VISSER, CA .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (09) :699-706
[16]   NONINVASIVE AORTIC BLOOD-FLOW MEASUREMENT USING AN INTRAESOPHAGEAL PROBE [J].
LAVANDIER, B ;
CATHIGNOL, D ;
MUCHADA, R ;
XUAN, BB ;
MOTIN, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (03) :451-460
[17]   ASSESSMENT OF A POTENTIALLY NONINVASIVE METHOD FOR MONITORING AORTIC BLOOD-FLOW IN CHILDREN [J].
LAVANDIER, B ;
MUCHADA, R ;
CHIGNIER, E ;
FADY, JF ;
BIRER, A ;
CATHIGNOL, D .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :107-116
[18]  
MARK JB, 1986, ANESTH ANALG, V65, P1013
[19]  
MUCHADA R, 1986, Annales Francaises d'Anesthesie et de Reanimation, V5, P14, DOI 10.1016/S0750-7658(86)80116-2
[20]  
MUCHADA R, 1988, American Journal of Noninvasive Cardiology, V2, P24