Accelerometry based assessment of gait parameters in children

被引:88
作者
Brandes, Mirko
Zijlstra, Wiebren
Heikens, Sander
van Lummel, Rob
Rosenbaum, Dieter
机构
[1] Univ Hosp Muenster, Dept Orthopaed, Movement Analysis Lab, D-48149 Munster, Germany
[2] Univ Groningen, Med Ctr, Ctr Human Movement Sci, Groningen, Netherlands
[3] McRoberts BV, The Hague, Netherlands
关键词
accelerometry; children; inverted pendulum model; steps; walking distance;
D O I
10.1016/j.gaitpost.2005.12.006
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The objective of this study was to examine if spatio-temporal gait parameters in healthy children can be determined from accelerations measured at the lower trunk as has been demonstrated in adults, previously. Twenty children aged 3-16 years, participated in a protocol that involved repeated walks of different distances in an indoor environment. During walking, accelerations were measured by three orthogonally mounted acceleration sensors in a small wireless device (DynaPort MiniMod) that was attached to the lower back. Based on an inverted pendulum approach, spatio-temporal gait parameters and walking distances were computed from the acceleration signals. Results were compared to video observations and known walking distances and durations. Steps were successfully detected in 99.6 +/- 0.6% of all observed steps (n = 5554). On average, walking distance was accurately estimated (100.6 +/- 3.3%, range 93-106.7%). No correlation was found between the number of miscounted steps and the total number of steps or the age of the subject. It can be concluded that the use of an inverted pendulum model provides the possibility to estimate spatio-temporal gait parameters in children as well as in adults. The method allows an inexpensive and comfortable assessment of gait parameters in children, is applicable in controlled, indoor environments and could be tested for applicability under free living conditions. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:482 / 486
页数:5
相关论文
共 13 条
[1]  
AMINIAN K, 1995, MED SCI SPORT EXER, V27, P226
[2]   Sensitivity and reproducibility of accelerometry and heart rate in physical strain assessment during prosthetic gait [J].
Bussmann, JBJ ;
van den Berg-Emons, HJG ;
Angulo, SM ;
Stijnen, T ;
Stam, HJ .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 91 (01) :71-78
[3]  
Chambers Henry G, 2002, J Am Acad Orthop Surg, V10, P222
[4]   The value of instrumented gait analysis in infantile cerebral palsy [J].
Döderlein L. ;
Wolf S. .
Der Orthopäde, 2004, 33 (10) :1103-1118
[5]   Using the gait laboratory for the investigation of orthopaedic clinical problems in children [J].
Lampe, R ;
Mitternacht, J ;
Schrödl, S ;
Gerdesmeyer, L ;
Nathrath, M ;
Gradinger, R .
KLINISCHE PADIATRIE, 2004, 216 (02) :72-78
[6]   A new method for evaluating motor control in gait under real-life environmental conditions. Part 2: Gait analysis [J].
Moe-Nilssen, R .
CLINICAL BIOMECHANICS, 1998, 13 (4-5) :328-335
[7]   Quantification of human motion: gait analysis - benefits and limitations to its application to clinical problems [J].
Simon, SR .
JOURNAL OF BIOMECHANICS, 2004, 37 (12) :1869-1880
[8]   The status of gait assessment among physiotherapists in the United Kingdom [J].
Toro, B ;
Nester, CJ ;
Farren, PC .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2003, 84 (12) :1878-1884
[9]   REAL-TIME GAIT ASSESSMENT UTILIZING A NEW WAY OF ACCELEROMETRY [J].
WILLEMSEN, ATM ;
VANALSTE, JA ;
BOOM, HBK .
JOURNAL OF BIOMECHANICS, 1990, 23 (08) :859-863
[10]   Assessment of spatio-temporal parameters during unconstrained walking [J].
Zijlstra, W .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 92 (1-2) :39-44