Comparison of hydrogen peroxide contact lens disinfection systems and solutions against Acanthamoeba polyphaga

被引:81
作者
Hughes, R [1 ]
Kilvington, S [1 ]
机构
[1] Univ Leicester, Dept Microbiol & Immunol, Leicester LE1 9HN, Leics, England
关键词
D O I
10.1128/AAC.45.7.2038-2043.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Acanthamoeba is a free-living amoeba causing a potentially blinding infection of the cornea, Contact lens wearers are most at risk and account for some 95% of cases. Hydrogen peroxide is used for contact lens disinfection due to its broad antimicrobial activity. Lenses must be neutralized before use to avoid pronounced stinging and possible corneal damage. Neutralization is achieved by adding a catalyst during the disinfection process tone-step) or afterwards (two-step). Here, the activities of commercial peroxide systems and individual solutions against trophozoites and cysts of Acanthamoeba polyphaga were compared. All disinfection systems were active against trophozoites, giving a greater than or equal to3-log (99.9%) kill within 1 h. Of the four one step systems, only one showed some cysticidal activity, giving a 1.28 +/- 0.41-log reduction. Both two-step systems were cysticidal, giving a greater than or equal to3-log kill at 4 h, All system peroxide solutions were cysticidal, giving a greater than or equal to3-log kill by 4 to 6 h, Variation in the cysticidal rate was observed with two solutions that gave a 1.8- to 2.1-log kill at 4 h compared with 3.0 to 4.0 for the rest (P < 0.05). No cysticidal activity was found with the peroxigen sodium perborate or the contact lens protein remover subtilisin A. Two-step systems are cysticidal providing contact times of at least 4 h are employed. Variation in cyst killing occurs between peroxide solutions, possibly due to formulation differences. One-step systems are less effective against Acanthamoeba cysts due to rapid peroxide neutralization, The cysticidal activity of one-step systems could be improved if neutralization rates were retarded.
引用
收藏
页码:2038 / 2043
页数:6
相关论文
共 27 条
[11]   VIRULENCE AND RESISTANCE TO SUPEROXIDE, LOW PH AND HYDROGEN-PEROXIDE AMONG STRAINS OF MYCOBACTERIUM-TUBERCULOSIS [J].
JACKETT, PS ;
ABER, VR ;
LOWRIE, DB .
JOURNAL OF GENERAL MICROBIOLOGY, 1978, 104 (JAN) :37-45
[12]  
Kilvington S., 1994, Reviews in Medical Microbiology, V5, P12
[13]   MOIST-HEAT DISINFECTION OF PATHOGENIC ACANTHAMOEBA CYSTS [J].
KILVINGTON, S .
LETTERS IN APPLIED MICROBIOLOGY, 1989, 9 (05) :187-189
[14]   ACTIVITY OF WATER BIOCIDE CHEMICALS AND CONTACT-LENS DISINFECTANTS ON PATHOGENIC FREE-LIVING AMEBAS [J].
KILVINGTON, S .
INTERNATIONAL BIODETERIORATION, 1990, 26 (2-4) :127-138
[15]   A comparison of cyst age and assay method of the efficacy of contact lens disinfectants against Acanthamoeba [J].
Kilvington, S ;
Anger, C .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (03) :336-340
[16]   ISOLATION OF AMOEBAE FROM AIR [J].
KINGSTON, D ;
WARHURST, DC .
JOURNAL OF MEDICAL MICROBIOLOGY, 1969, 2 (01) :27-+
[17]  
LOWE R, 1992, CLAO Journal, V18, P34
[18]  
LUDWIG IH, 1986, INVEST OPHTH VIS SCI, V27, P626
[19]  
MARTINEZ AJ, 1991, REV INFECT DIS, V13, pS399
[20]  
Neff R, 1964, METHOD CELL PHYSIOL, P55, DOI DOI 10.1016/S0091-679X(08)62086-5