Calibration of accelerometer output for adults

被引:534
作者
Matthews, CE [1 ]
机构
[1] Vanderbilt Univ, Vanderbilt Ingram Canc Ctr, Sch Med,Ctr Hlth Serv Res, Div Gen Internal Med,Dept Med,Med Ctr E, Nashville, TN 37232 USA
关键词
physical activity; exercise; ambulatory monitoring; behavior; energy expenditure;
D O I
10.1249/01.mss.0000185659.11982.3d
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This paper reviews the collective experience of monitor calibration studies in adults and seeks to answer the following questions: What has been done? What have we learned? What could be done to further enhance the comparability of results from future calibration research? Calibration studies in adults have typically used oxygen consumption as a criterion measure, similar types of source activities, and linear regression to obtain prediction equations that calibrate the activity counts to measured activity intensity levels. However, the methodological diversity of these studies has produced a great deal of variation in the resulting prediction equations and cut points, even when using the same monitor. Thus, data obtained from a relatively robust activity monitoring technology that captures many dynamic physical activities reasonably well have been splintered by the calibration process into a wide range of summary measures that are much less comparable than they could otherwise be. This heterogeneity in calibration results reduces our ability to interpret data obtained from accelerometers between different research groups, across the life span, between populations, and probably between the different monitor types. This report reviews and critiques methods typically used for developing calibration equations and determining activity count cut points for identifying specific intensities of PA among adults, and it highlights the need for flexible research methods that can enhance the comparability of results from future calibration studies.
引用
收藏
页码:S512 / S522
页数:11
相关论文
共 43 条
[1]   Comparison of three methods for measuring the time spent in physical activity [J].
Ainsworth, BE ;
Bassett, DR ;
Strath, SJ ;
Swartz, AM ;
O'Brien, WL ;
Thompson, RW ;
Jones, DA ;
Macera, CA ;
Kimsey, CD .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S457-S464
[2]  
Ayen TG, 1988, J AMBULATORY MONIT, V1, P293
[3]   Validity and reliability issues in objective monitoring of physical activity [J].
Bassett, DR .
RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2000, 71 (02) :S30-S36
[4]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[5]   Daily physical activity assessment: Comparison between movement registration and doubly labeled water [J].
Bouten, CVC ;
VerboeketVandeVenne, WPHG ;
Westerterp, KR ;
Verduin, M ;
Janssen, JD .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (02) :1019-1026
[6]   A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity [J].
Bouten, CVC ;
Koekkoek, KTM ;
Verduin, M ;
Kodde, R ;
Janssen, JD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) :136-147
[7]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[8]   Field evaluation of energy expenditure in women using Tritrac accelerometers [J].
Campbell, KL ;
Crocker, PRE ;
McKenzie, DC .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (10) :1667-1674
[9]   Improving energy expenditure estimation by using a triaxial accelerometer [J].
Chen, KY ;
Sun, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (06) :2112-2122
[10]   The technology of accelerometry-based activity monitors: Current and future [J].
Chen, KY ;
Bassett, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11) :S490-S500