Validity and reliability issues in objective monitoring of physical activity

被引:206
作者
Bassett, DR [1 ]
机构
[1] Univ Tennessee, Dept Exercise Sci & Sport Management, Knoxville, TN 37996 USA
关键词
physical activity; pedometers; heart rate monitoring; accelerometers;
D O I
10.1080/02701367.2000.11082783
中图分类号
F [经济];
学科分类号
02 ;
摘要
Major technical advances have occurred within the last 10 years in the field of physical activity monitoring.The biggest one is real-time data acquisition, and thedevelopment of computer microchips that allow vastamounts of information to be stored and later recalled.It is evident that no single motion sensor will provide anaccurate estimate of energy expenditure across all activities.Future directions for research include the use ofcombined instruments such as an accelerometer plusquestionnaire, multiple motion sensors, or dual HRmotionsensor technology. © 2000 by the American Alliance for Health, Physical Education, Recreation and Dance.
引用
收藏
页码:S30 / S36
页数:7
相关论文
共 38 条
  • [1] [Anonymous], PEDIAT EXERCISE SCI
  • [2] CALORIMETRIC VALIDATION OF THE CALTRAC ACCELEROMETER DURING LEVEL WALKING
    BALOGUN, JA
    MARTIN, DA
    CLENDENIN, MA
    [J]. PHYSICAL THERAPY, 1989, 69 (06): : 501 - 509
  • [3] Accuracy of five electronic pedometers for measuring distance walked
    Bassett, DR
    Ainsworth, BE
    Leggett, SR
    Mathien, CA
    Main, JA
    Hunter, DC
    Duncan, GE
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (08) : 1071 - 1077
  • [4] BASSETT DR, IN PRESS MED SCI SPO
  • [5] Batty D, 1998, NEW ENGL J MED, V338, P1622
  • [6] Heart rate recording method validated by whole body indirect calorimetry in 10-yr-old children
    Bitar, A
    Vermorel, M
    Fellmann, N
    Bedu, M
    Chamoux, A
    Coudert, J
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (03) : 1169 - 1173
  • [7] CASPERSEN CJ, 1989, EXERCISE SPORT SCI R, V17, P423
  • [8] THE USE OF HEART-RATE MONITORING IN THE ESTIMATION OF ENERGY-EXPENDITURE - A VALIDATION-STUDY USING INDIRECT WHOLE-BODY CALORIMETRY
    CEESAY, SM
    PRENTICE, AM
    DAY, KC
    MURGATROYD, PR
    GOLDBERG, GR
    SCOTT, W
    SPURR, GB
    [J]. BRITISH JOURNAL OF NUTRITION, 1989, 61 (02) : 175 - 186
  • [9] COMPARISON OF HEART-RATE MONITORING COMBINED WITH INDIRECT CALORIMETRY AND THE DOUBLY LABELED WATER (2H2O)-O-18) METHOD FOR THE MEASUREMENT OF ENERGY-EXPENDITURE IN CHILDREN
    EMONS, HJG
    GROENENBOOM, DC
    WESTERTERP, KR
    SARIS, WHM
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1992, 65 (02): : 99 - 103
  • [10] Calibration of the Computer Science and Applications, Inc. accelerometer
    Freedson, PS
    Melanson, E
    Sirard, J
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (05) : 777 - 781