Laser desorption-atmospheric pressure chemical ionization mass spectrometry for the analysis of peptides from aqueous solutions

被引:37
作者
Coon, JJ [1 ]
Harrison, WW [1 ]
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
关键词
D O I
10.1021/ac020402k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A recently reported ionization method, comprising an infrared (IR) laser pulse to desorb (LD) analyte species, followed by atmospheric pressure chemical ionization (APCI) with a corona discharge (LD-APCI) to effect ionization of the desorbed neutral analyte molecules, is described for the direct analysis of aqueous peptide solutions. The source employs a heated capillary atmospheric pressure (AP) inlet coupled to a quadrupole ion trap mass spectrometer and allows sampling under normal ambient air conditions. By use of the corona discharge, signals of the atmospheric pressure infrared matrix-assisted laser desorption/ionization (AP-IR-MALDI)-generated analyte protonated molecule were enhanced by factors as large as 1400. In addition, the acid modifier trifluoroacetic acid (TFA) was found to improve the AP-IR-MALDI-generated signal by a factor of similar to10, whereas the LD-APCI generated signal yielded a 100-fold increase. In this study, the use of the corona discharge is described to enhance the analyte signal generated via AP-IR-MALDI and, as a tool, to probe the gas-phase neutral molecule population generated by the MALDI process. Finally, through the decoupling of desorption from ionization, implications regarding the application of LD-APCI for the direct analysis of numerous new analyte containing matrixes (e.g., polyacrylamide gel electrophoresis (PAGE), tissue, etc.) are discussed.
引用
收藏
页码:5600 / 5605
页数:6
相关论文
共 35 条
[1]  
Beavis R C, 1989, Rapid Commun Mass Spectrom, V3, P432, DOI 10.1002/rcm.1290031207
[2]   Chemical ionization of neutral peptides produced by matrix-assisted laser desorption [J].
Belov, ME ;
Myatt, CP ;
Derrick, PJ .
CHEMICAL PHYSICS LETTERS, 1998, 284 (5-6) :412-418
[3]  
Berkenkamp S, 1997, RAPID COMMUN MASS SP, V11, P1399
[4]   Mid-infrared matrix assisted laser desorption ionization with a water/glycerol matrix [J].
Caldwell, KL ;
Murray, KK .
APPLIED SURFACE SCIENCE, 1998, 127 :242-247
[5]   Atmospheric pressure laser desorption/chemical ionization mass spectrometry: a new ionization method based on existing themes [J].
Coon, JJ ;
McHale, KJ ;
Harrison, WW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (07) :681-685
[6]  
COON JJ, UNPUB J MASS SPECTRO
[7]  
COON JJ, 2002, P 50 ASMS C MASS SPE
[8]  
COON JJ, 2001, P 49 ASMS C MASS SPE
[9]  
COON JJ, 2001, 17 AS C MASS SPECTR
[10]  
COON JJ, 2000, P 48 ASMS C MASS SPE