A rough surface finish adversely affects the survivorship of a cemented femoral stem

被引:36
作者
Della Valle, AG
Zoppi, A
Peterson, MGE
Salvati, EA
机构
[1] Hosp Special Surg, New York, NY 10021 USA
[2] Civil Hosp Velletri, Dept Orthopaed, Rome, Italy
关键词
D O I
10.1097/01.blo.0000160684.87415.d9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To assess the role of surface finish in the survivorship of a cemented femoral stem, we evaluated the midterm clinical and radiographic performances of a cohort of patients who had total hip arthroplasties with two cemented femoral stems that differed only in surface finish. One hundred seventy-five patients [64 total hip arthroplasties with rough, textured stems (radius, 1.75-2.5 mu m) and 138 total hip arthroplasties with satin finish, textured stems (radius, 0.5 mu m)] were followed up clinically and radiographically for 4-8 years. All surgeries were done by one surgeon using the same surgical technique, acetabular cup, cement type, and cementing technique. The groups had similar demographics, diagnoses, preoperative clinical scores, cement mantle qualities, alignments, and lengths of followup. Seven hips in the rough surface group and none in the satin surface group had aseptic loosening. The femoral bone-cement interface showed progressive radiolucent lines or osteolysis in eight of 64 rough stems and in three of 138 satin stems. A rough, textured stem of this design is more likely to fail at intermediate followup than a satin surface stem. We recommend that the surface of cemented stems should be satin or polished with a radius less than 0.5 mu m.
引用
收藏
页码:158 / 163
页数:6
相关论文
共 27 条
[1]
METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[3]
IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW [J].
BARRACK, RL ;
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :385-389
[4]
Buly R L, 1992, J Arthroplasty, V7, P315, DOI 10.1016/0883-5403(92)90056-V
[5]
CALLAGHAN JJ, 1996, CLIN ORTHOP RELAT R, V333, P118
[6]
Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry [J].
Collis, DK ;
Mohler, CG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (04) :586-592
[7]
CROWNINSHIELD RD, 1998, CLIN ORTHOP RELAT R, V355, P90
[8]
FRACTURE AND LOOSENING OF CHARNLEY FEMORAL STEMS - COMPARISON BETWEEN 1ST-GENERATION AND SUBSEQUENT DESIGNS [J].
DALL, DM ;
LEARMONTH, ID ;
SOLOMON, MI ;
MILES, AW ;
DAVENPORT, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :259-265
[9]
Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty [J].
Della Valle, AG ;
Zoppi, A ;
Peterson, MGE ;
Salvati, EA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (09) :1998-2004
[10]
DOWD JE, 1998, CLIN ORTHOP RELAT R, V355, P123