Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty

被引:61
作者
Della Valle, AG [1 ]
Zoppi, A [1 ]
Peterson, MGE [1 ]
Salvati, EA [1 ]
机构
[1] Hosp Special Surg, New York, NY 10021 USA
关键词
D O I
10.2106/00004623-200409000-00019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: First-generation cementless modular cups reproducibly achieved fixation to bone but were associated with unacceptable rates of pelvic osteolysis and mechanical failure. Consequently, second-generation cups were developed with shells that had a limited number of holes (or no holes) as well as improved locking mechanisms, a polished inner surface, and increased conformity with the liner. The purpose of the present study was to evaluate the clinical and radiographic results associated with the use of a second-generation acetabular component for primary total hip arthroplasty. Methods: Two hundred and ninety-seven patients underwent 335 consecutive primary total hip arthroplasties that were performed by a single surgeon with a second-generation modular acetabular component. All cups were implanted with a press-fit technique. Ten patients were lost to follow-up, and sixteen died from unrelated causes. The remaining 271 patients (308 hips) were followed clinically (with the Hospital for Special Surgery hip-scoring system) and radiographically for four to seven years. Results: One cup was revised because of aseptic loosening. There were seven additional revisions: five were performed because of aseptic loosening of the stem with a well-fixed cup, and two were performed because of deep infection. Among the 271 patients who were alive at the time of the last follow-up, 266 (98%) had retention of the cup and 264 (97%) had retention of both components with a good or excellent clinical result. In the group of 229 patients (262 hips) with complete radiographic follow-up, 259 cups were well fixed and the average wear rate (for the 246 hips for which this rate could be calculated) was 0.09 mm/yr. Osteolysis was detected in twelve hips (5%) and was associated with male gender (p = 0.001) and the annual wear rate (p = 0.004). The extent of calcar resorption was also associated with the annual wear rate (p < 0.001). Conclusions: This second-generation acetabular cup design predictably achieved bone fixation and was associated with low rates of revision for loosening and osteolysis after intermediate-term follow-up. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1998 / 2004
页数:7
相关论文
共 20 条
[1]
ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]
Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements - Factors affecting survivorship of acetabular and femoral components [J].
Berry, DJ ;
Harmsen, WS ;
Cabanela, ME ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (02) :171-177
[3]
Bono J V, 1994, J Arthroplasty, V9, P119, DOI 10.1016/0883-5403(94)90059-0
[4]
Radiographic definition of pelvic osteolysis following total hip arthroplasty [J].
Claus, AM ;
Engh, CA ;
Sychterz, CJ ;
Xenos, JS ;
Orishimo, KF ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (08) :1519-1526
[5]
Pattern of osteolysis around two different cementless metal-backed cups - Retrospective, radiographic analysis at minimum 10-year follow-up [J].
Claus, AM ;
Sychterz, CJ ;
Hopper, RH ;
Engh, CA .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :177-182
[6]
Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old - Results at nine to fourteen years [J].
Crowther, JD ;
Lachiewicz, PF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (05) :729-735
[7]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[8]
Dislodgment of polyethylene liners in first and second-generation Harris-Galante acetabular components - A report of eighteen cases [J].
Della Valle, AG ;
Ruzo, PS ;
Li, S ;
Pellicci, P ;
Sculco, TP ;
Salvati, EA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (04) :553-559
[9]
Heterotopic ossification after total hip arthroplasty - A critical analysis of the Brooker classification and proposal of a simplified rating system [J].
Della Valle, AG ;
Ruzo, PS ;
Pavone, V ;
Tolo, E ;
Mintz, DN ;
Salvati, EA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (07) :870-875
[10]
Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty [J].
Hui, AJ ;
McCalden, FW ;
Martell, JM ;
MacDonald, SJ ;
Bourne, RB ;
Rorabeck, CH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (03) :505-511