Development of a four-channel potentiostat for amperometric detection in flow injection analysis

被引:10
作者
Matos, RC [1 ]
Angnes, L [1 ]
do Lago, CL [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05508900 Sao Paulo, Brazil
关键词
D O I
10.1080/10739149808000913
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A four-channel multipotentiostat has been developed for simultaneous voltammetric measurements with microelectrode arrays. To reduce the complexity of electrochemical cell, only one reference and one auxiliary electrode are used. The potential ranges of the four working electrodes may be independently controlled, but they are synchronously scanned by only one DAC. This is accomplished through a microcomputer interfaced with a PCL-711B data acquisition board, which allows the continuous monitoring of the currents and actual potentials of the working electrodes. The system has been applied to the simultaneous determination of ascorbic and uric acids in synthetic samples. The measurements were carried out with gold microelectrodes modified by deposition of noble metals, which enhance the electrocatalysis and provide an anticipation and a better definition of the oxidation potentials. Recuperation of 98.2 % and 97.8 % for ascorbic and uric acids, respectively, was obtained by using amperometry.
引用
收藏
页码:451 / 459
页数:9
相关论文
共 15 条
[1]   MULTICHANNEL ELECTROCHEMICAL DETECTION WITH A MICROELECTRODE ARRAY IN FLOWING STREAMS [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :44-49
[2]   ELECTROCHEMICAL RESPONSE AT MICROARRAY ELECTRODES IN FLOWING STREAMS AND DETERMINATION OF CATECHOLAMINES [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2206-2210
[3]   Flow-through cell based on an array of gold microelectrodes obtained from modified integrated circuit chips [J].
Augelli, MA ;
Nascimento, VB ;
Pedrotti, JJ ;
Gutz, IGR ;
Angnes, L .
ANALYST, 1997, 122 (08) :843-847
[4]   EXPERIMENTAL-OBSERVATIONS OF FREE-CONVECTION MASS-TRANSFER TO A HORIZONTAL SURFACE WITH A MICROMOSAIC ELECTRODE [J].
DEES, DW ;
TOBIAS, CW .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (02) :369-377
[5]   DEVELOPMENT OF A COMPUTER-CONTROLLED MULTICHANNEL POTENTIOSTAT FOR APPLICATIONS WITH FLOWING SOLUTION ANALYSIS [J].
FANG, T ;
MCGRATH, M ;
DIAMOND, D ;
SMYTH, MR .
ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) :347-358
[6]  
FARIAS LC, 1991, QUIM NOVA, V14, P216
[7]   VOLTAMMETRIC INFORMATION FROM ARRAYS OF INDIVIDUALLY CONTROLLED ELECTRODES - THEIR POTENTIAL FOR INDUSTRIAL-PROCESS MEASUREMENTS [J].
FIELDEN, PR ;
MCCREEDY, T .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :111-121
[8]   MULTICHANNEL AMPEROMETRIC DETECTION SYSTEM FOR LIQUID-CHROMATOGRAPHY AND FLOW-INJECTION ANALYSIS [J].
HOOGVLIET, JC ;
REIJN, JM ;
VANBENNEKOM, WP .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2418-2423
[9]   COULOSTATIC VOLTAMMETRIC LIQUID-CHROMATOGRAPHY DETECTOR [J].
LAST, TA .
ANALYTICAL CHEMISTRY, 1983, 55 (09) :1509-1512
[10]  
MATOS RC, 1996, ANAIS SOCIEDADE BRAS