FTIR transmission emission spectroscopy of gases at high temperatures: Experimental set-up and analytical procedures

被引:18
作者
Clausen, S [1 ]
Bak, J [1 ]
机构
[1] Riso Natl Lab, Opt & Fluid Dynam Dept, DK-4000 Roskilde, Denmark
关键词
D O I
10.1016/S0022-4073(97)00205-7
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An experimental laboratory set-up for high-temperature gas analysis is presented. The set-up, which comprises an FTIR instrument with an internal detector, an external blackbody source and a heated gas cell, can be used to measure the transmissive and emissive properties of gases at elevated temperatures. The stainless-steel cell designed for this work was heated to temperatures ranging from 294 to 1273 K. Measurements of the spectral transmittance and radiance (4 cm(-1)) of heated carbon dioxide (CO2) in various concentrations (0.5, 10, 100 vol%) were performed to test the experimental set-up. A solution to the problem is given of how to express analytically both the transmitted and especially the emitted radiation of a heated gas sample enclosed in a gas cell. In order to measure the gas radiation, it is necessary to measure the wave-number-dependent thermal radiation from the heated sapphire gas cell windows. It is shown that the gas temperature can be determined at low temperatures (473 K), if the measured thermal radiation of the gas is corrected for the thermal radiation emitted by the FTIR instrument. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:131 / 141
页数:11
相关论文
共 12 条
[1]   THE EFFECT OF SAMPLE EMISSION ON MEASUREMENTS OF SPECTRAL PARAMETERS USING A FOURIER-TRANSFORM ABSORPTION SPECTROMETER [J].
BALLARD, J ;
REMEDIOS, JJ ;
ROSCOE, HK .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1992, 48 (5-6) :733-741
[2]   APPARATUS FOR THE DETERMINATION OF THE BAND ABSORPTION OF GASES AT ELEVATED PRESSURES AND TEMPERATURES [J].
BEVANS, JT ;
DUNKLE, RV ;
EDWARDS, DK ;
GIER, JT ;
LEVENSON, LL ;
OPPENHEIM, AK .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1960, 50 (02) :130-136
[3]   FOURIER TRANSFORM VERSUS GRATING SPECTROSCOPY [J].
GEBBIE, HA .
APPLIED OPTICS, 1969, 8 (03) :501-&
[4]  
HARRIS DC, 1992, INFRARED WINDOW DOME, P23
[5]  
KOSHLAND CP, 1992, P 24 S INT COMB COMB, P1597
[6]   APPLICATION OF FT-IR ABSORPTION-SPECTROSCOPY FOR IN-SITU GAS CONCENTRATION AND TEMPERATURE-MEASUREMENTS IN LABORATORY-SCALE AND PILOT-SCALE COMBUSTION ENVIRONMENTS [J].
MARTIN, DM ;
MEDVECZ, PJ ;
NICHOLS, KM .
APPLIED SPECTROSCOPY, 1993, 47 (11) :1898-1906
[7]   DETERMINATION OF GAS TEMPERATURES AT 295-K-1273-K USING CO VIBRATIONAL-ROTATIONAL ABSORPTION-SPECTRA RECORDED WITH AN FT-IR SPECTROMETER [J].
MEDVECZ, PJ ;
NICHOLS, KM ;
CLAY, DT ;
ATALLA, R .
APPLIED SPECTROSCOPY, 1991, 45 (08) :1350-1359
[8]  
MORRISON PW, 1991, TAPPI J, V74, P68
[9]   RADIOMETRIC CALIBRATION OF IR FOURIER-TRANSFORM SPECTROMETERS - SOLUTION TO A PROBLEM WITH THE HIGH-RESOLUTION INTERFEROMETER SOUNDER [J].
REVERCOMB, HE ;
BUIJS, H ;
HOWELL, HB ;
LAPORTE, DD ;
SMITH, WL ;
SROMOVSKY, LA .
APPLIED OPTICS, 1988, 27 (15) :3210-3218
[10]   MEASUREMENTS AND CALCULATIONS OF CO2 ABSORPTION AT HIGH-TEMPERATURE IN THE 4.3 AND 2.7 MU-M REGIONS [J].
SCUTARU, D ;
ROSENMANN, L ;
TAINE, J ;
WATTSON, RB ;
ROTHMAN, LS .