The membrane free sonoelectroanalytical determination of trace levels of lead and cadmium in human saliva

被引:27
作者
Hardcastle, JL [1 ]
West, CE [1 ]
Compton, RG [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
D O I
10.1039/b204886h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, square wave anodic stripping voltammetry (SWASV), synergistically coupled with an ultrasonically enhanced preconcentration step has been shown to yield a quantitative determination of lead and cadmium in human saliva at a membrane free in situ plated mercury thin film glassy carbon electrode. The sensitivity was facilitated by acoustic streaming which promoted efficient mass transport to the electrode thus reducing sampling times. Cavitation was responsible for cleaning and activating the electrode surface, this was essential in order to obtain a reproducible and representative signal. In silent conditions electrode fouling leading to fluctuations in the baseline current and signal depression, precluded accurate quantitative analyses. The results presented herein provide an extension to the proof of concept given in the authors' earlier work, with the analysis of lead in human saliva as opposed to artificial saliva reported. We also address the hitherto unreported detection and determination of cadmium in this medium. Results for both were independently verified by inductively coupled plasma-mass spectroscopy (ICP-MS). Close agreement between lead concentration determined by sono-SWASV and independent and blind ICP-MS is reported for human saliva samples having a total lead content of 0.92 mug L-1 and 5 mug L-1 with a detection limit of 0.5 mug L-1. Microaddition calibration data for cadmium additions of 0.0125 mug L-1 to samples spiked with 2.5 mug L-1 and 5.0 mug L-1 (reflecting levels in workers occupationally exposed) exhibited close agreement with the known total cadmium in the samples. A detection limit of 1 mug L-1 cadmium in saliva has been established.
引用
收藏
页码:1495 / 1501
页数:7
相关论文
共 61 条
[1]   Anodic stripping voltammetry of copper at insonated glassy carbon-based electrodes:: application to the determination of copper in beer [J].
Agra-Gutiérrez, C ;
Hardcastle, JL ;
Ball, JC ;
Compton, RG .
ANALYST, 1999, 124 (07) :1053-1057
[2]  
Agra-Gutierrez C, 1998, ELECTROANAL, V10, P603, DOI 10.1002/(SICI)1521-4109(199807)10:9<603::AID-ELAN603>3.3.CO
[3]  
2-D
[4]  
Agra-Gutierroz C, 1998, ELECTROANAL, V10, P204, DOI 10.1002/(SICI)1521-4109(199803)10:3<204::AID-ELAN204>3.0.CO
[5]  
2-F
[6]   Sono-electroanalysis: Application to the detection of lead in wine [J].
Akkermans, RP ;
Ball, JC ;
Rebbitt, TO ;
Marken, F ;
Compton, RG .
ELECTROCHIMICA ACTA, 1998, 43 (23) :3443-3449
[7]  
[Anonymous], 1978, ATOMIC ABSORPTION FL
[8]   Toxicity of cadmium in tobacco smoke:: Protection by antioxidants and chelating resins [J].
Bachelet, M ;
Pinot, F ;
Polla, RI ;
François, D ;
Richard, MJ ;
Vayssier-Taussat, M ;
Polla, BS .
FREE RADICAL RESEARCH, 2002, 36 (01) :99-106
[9]   Salivary protein adsorption onto hydroxyapatite and SDS-mediated elution studied by in situ ellipsometry [J].
Berg, ICH ;
Elofsson, UM ;
Joiner, A ;
Malmsten, M ;
Arnebrant, T .
BIOFOULING, 2001, 17 (03) :173-187
[10]   INFLUENCE OF REMOVAL FROM OCCUPATIONAL LEAD-EXPOSURE ON BLOOD AND SALIVA LEAD CONCENTRATIONS [J].
BRODEUR, J ;
LACASSE, Y ;
TALBOT, D .
TOXICOLOGY LETTERS, 1983, 19 (1-2) :195-199