摘要
Matrix interferences in inductively coupled plasma mass spectrometry (ICP-MS) were examined to extend the total interference level (TIL) concept from ICP-AES. The TIL model is based on measurements with different interferents to determine a set of interference coefficients. Interference is assumed to be linear with interferent concentration, since that assumption allows determination of the model parameters with the fewest experiments. The TIL model was designed to indicate when a simple external standards calibration method is inadequate for a desired level of analytical accuracy and was also tested on a simple form of internal standards. The TIL concept was tested in both an initial calibration and a daily calibration mode on the interferents Na, K, Al, Ba and Cs and works well for situations where external standards are used, recommending an inaccurate method for only 3% of cases where 10% accuracy was desired. The TIL model also works well with the very different calibration technique of internal standards, recommending an inaccurate method for 9% of cases where 10% accuracy was desired.
引用
收藏
页码:617 / 625
页数:9
相关论文
共 16 条
[11]   Investigating the fate of individual sample droplets in inductively coupled plasmas [J].
Olesik, JW .
APPLIED SPECTROSCOPY, 1997, 51 (05) :A158-A175
[12]   SUPPRESSION OF ANALYTE SIGNAL BY VARIOUS CONCOMITANT SALTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
OLIVARES, JA ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :20-25
[13]   Automatic selection of internal standards in inductively coupled plasma-mass spectrometry [J].
Sartoros, C ;
Salin, ED .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (11) :1557-1571
[14]   MATRIX-EFFECT OBSERVATIONS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
TAN, SH ;
HORLICK, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (08) :745-763
[15]   THE USE OF INTERNAL STANDARDS IN ICP MS [J].
VANHAECKE, F ;
VANHOE, H ;
DAMS, R ;
VANDECASTEELE, C .
TALANTA, 1992, 39 (07) :737-742
[16]   THE AUTONOMOUS INSTRUMENT - A DESIGN [J].
WEBB, DP ;
HAMIER, J ;
SALIN, ED .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (02) :44-53