Determination of 4-ethylguaiacol and 4-ethylphenol in red wines using headspace-solid-phase microextraction-gas chromatography

被引:80
作者
Martorell, N [1 ]
Martí, MP [1 ]
Mestres, M [1 ]
Busto, O [1 ]
Guasch, J [1 ]
机构
[1] Univ Rovira Virgili, Fac Enol Tarragona, Unitat Enol CeRTA, Dept Quim Analit & Quim Organ, Tarragona 43005, Spain
关键词
wine; solid-phase microextraction; headspace analysis; 4-ethylguaiacol; 4-ethylphenol;
D O I
10.1016/S0021-9673(02)01277-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for analysing 4-ethylguaiacol and 4-ethylphenol in the aroma of red wines using headspace-solid-phase microextraction is presented. The fibres used were coated with 100 mum of polydimethylsiloxane. Parameters like ionic strength, agitation of the sample, sample volume, temperature of the sample and adsorption/ desorption times were studied and optimised to obtain the best extraction results. The linearity of the response was studied in the usual concentration ranges in wines (4-ethylguaiacol, 40-400 mug/l; 4-ethylphenol, 200-1800 mug/l). Repeatability of the method was determined, and the relative standard deviation was about 10%. Limits of detection and limits of quantification were also determined, and the values found were 1 and 5 mug/l for 4-ethylguaiacol and 2 and 5 mug/l for 4-ethylphenol, respectively. All these values were under the sensory thresholds established for these volatile phenols. The presence of interferences due to the matrix composition implies the use of the standard addition technique for both compounds quantification. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:349 / 354
页数:6
相关论文
共 24 条
[1]  
[Anonymous], ANAL FOODS BEVERAGES
[2]  
BOQUE R, 1994, J CHEM ED COMPUT SER, V70, P230
[3]  
CHATONNET P, 1990, SCI ALIMENT, V10, P565
[4]  
Etievant P.X., 1991, Volatile Compounds in Foods and Beverages, P483, DOI DOI 10.1201/9780203734285
[5]   FAST AND QUANTITATIVE-DETERMINATION OF WINE FLAVOR COMPOUNDS USING MICROEXTRACTION WITH FREON-113 [J].
FERREIRA, V ;
RAPP, A ;
CACHO, JF ;
HASTRICH, H ;
YAVAS, I .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (09) :1413-1420
[6]   Analysis of cork taint in wine and cork material at olfactory subthreshold levels by solid phase microextraction [J].
Fischer, C ;
Fischer, U .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (06) :1995-1997
[7]  
GONZALEZ M, 1985, ALIMENT EQUIP TECNOL, V5, P131
[8]   Applications of solid-phase microextraction in food analysis [J].
Kataoka, H ;
Lord, HL ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 880 (1-2) :35-62
[9]  
Lewi P.J., 1997, HDB CHEMOMETRICS QUA, V20A
[10]  
MASSART DL, 1988, CHEMOMETRICS TXB DAT, V2, P79