Differential pulse voltammetric determination of paracetamol at nanogold modified indium tin oxide electrode

被引:288
作者
Goyal, RN [1 ]
Gupta, VK
Oyama, M
Bachheti, N
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[2] Kyoto Univ, Div Res Initiat, Int Innovat Ctr, Sakyo Ku, Kyoto 6068501, Japan
基金
日本学术振兴会;
关键词
nanogold modified indium tin oxide electrode; paracetamol; differential pulse voltammetry; pharmaceutical preparations;
D O I
10.1016/j.elecom.2005.05.005
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A nanogold modified indium tin oxide (ITO) electrode was used for the determination of paracetamol at pH 7.2. The electrode exhibited an effective catalytic response to the oxidation of paracetamol with good reproducibility and stability. Under conditions of differential pulse voltammetry, the oxidation potential of paracetamol is lowered by approximately 110 mV and current response is enhanced significantly relative to the situation prevailing when a bare ITO electrode is used. Linear calibration curve is obtained over the range 2.0 x 10(-7)-1.5 x 10(-3) M with a correlation coefficient of 0.997. The detection limit (3 sigma) was estimated to be 1.8 x 10(-7) M. The physiologically common interferents viz., ascorbic acid, glucose and urea negligibly affected the current response of paracetamol. The practical analytical utility of the method is illustrated by determination of paracetamol in pharmaceutical preparations. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:803 / 807
页数:5
相关论文
共 33 条
[1]  
Bi S., 2000, ZIRAN KEXUEBAN, V26, P110
[2]   Paracetamol in the treatment of osteoarthritis pain [J].
Brandt, K .
DRUGS, 2003, 63 :23-41
[3]   Fast determination of paracetamol by using a very simple photometric flow-through sensing device [J].
Cañada, MJA ;
Reguera, MIP ;
Medina, AR ;
de Córdova, MLF ;
Díaz, AM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (01) :59-66
[4]  
Christian G.D., 1962, JELECTROANAL CHEM, V3, P363, DOI [10.1016/0022-0728(62)80012-6, DOI 10.1016/0022-0728(62)80012-6]
[5]   DIRECT ELECTROCHEMICAL DETERMINATION OF PARACETAMOL IN PLASMA [J].
CHRISTIE, I ;
LEEDS, S ;
BAKER, M ;
KEEDY, F ;
VADGAMA, P .
ANALYTICA CHIMICA ACTA, 1993, 272 (01) :145-150
[6]   PARACETAMOL AND PHENACETIN [J].
CLISSOLD, SP .
DRUGS, 1986, 32 :46-59
[7]   Over-the-counter analgesics and risk of ovarian cancer [J].
Cramer, DW ;
Harlow, BL ;
Titus-Ernstoff, L ;
Bohlke, K ;
Welch, WR ;
Greenberg, ER .
LANCET, 1998, 351 (9096) :104-107
[8]   RAPID DETECTION OF PARACETAMOL USING A DISPOSABLE, SURFACE-MODIFIED SCREEN-PRINTED CARBON ELECTRODE [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1994, 119 (11) :2431-2437
[9]   Attachment of gold nanoparticles to glassy carbon electrodes via a mercaptobenzene film [J].
Harnisch, JA ;
Pris, AD ;
Porter, MD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (24) :5829-5830
[10]   Poly(dimethylsiloxane) microchip capillary electrophoresis with electrochemical detection for rapid measurement of acetaminophen and its hydrolysate [J].
He, FY ;
Liu, AL ;
Xia, XH .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (7-8) :1062-1067