Evaluation of different tubing geometries for high-speed counter-current chromatography

被引:16
作者
Degenhardt, A
Schwarz, M
Winterhalter, P
Ito, Y
机构
[1] Tech Univ Braunschweig, Inst Food Technol, DE-38106 Braunschweig, Germany
[2] NHLBI, Biophys Chem Lab, NIH, Bethesda, MD 20892 USA
关键词
counter-current chromatography; column geometry; partition efficiency; efficiency; instrumentation; anthocyanins;
D O I
10.1016/S0021-9673(01)00908-6
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Different tubing geometries were evaluated for use in high-speed counter-current chromatography. Standard round tubing was compared to rectangular and twisted rectangular tubing. The number of theoretical plates for a standard anthocyanin mixture from black currant was determined for each experiment. The results of twisted rectangular tubing were superior to a standard setup. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:355 / 358
页数:4
相关论文
共 9 条
[1]
Conway WD., 1990, COUNTERCURRENT CHROM
[2]
Separation and purification of anthocyanins by high-speed countercurrent chromatography and screening for antioxidant activity [J].
Degenhardt, A ;
Knapp, H ;
Winterhalter, P .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (02) :338-343
[3]
Low speed rotary countercurrent chromatography using a convoluted multilayer helical tube for industrial separation [J].
Du, QZ ;
Wu, PD ;
Ito, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3363-3365
[4]
Relationship between the flow-rate of the mobile phase and retention of the stationary phase in counter-current chromatography [J].
Du, QZ ;
Wu, CJ ;
Qian, GJ ;
Wu, PD ;
Ito, Y .
JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) :231-235
[5]
SPECULATION ON THE MECHANISM OF UNILATERAL HYDRODYNAMIC DISTRIBUTION OF 2 IMMISCIBLE SOLVENT PHASES IN THE ROTATING COIL [J].
ITO, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (15-16) :2639-2675
[6]
ITO Y, 1986, CRIT REV ANAL CHEM, V17, P65, DOI 10.1080/10408348608542792
[7]
IMPROVED SCHEME FOR PREPARATIVE COUNTERCURRENT CHROMATOGRAPHY (CCC) WITH A ROTATING COIL ASSEMBLY [J].
ITO, Y ;
BHATNAGAR, R .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (02) :257-273
[8]
DISCREPANCY BETWEEN THE THEORETICAL PLATE NUMBER (N) AND PEAK RESOLUTION (RS) FOR OPTIMIZING THE FLOW-RATE IN COUNTERCURRENT CHROMATOGRAPHY [J].
OKA, H ;
IKAI, Y ;
HAYAKAWA, J ;
HARADA, K ;
NAGASE, K ;
SUZUKI, M ;
NAKAZAWA, H ;
ITO, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (15-16) :2707-2719
[9]
EVALUATION OF ANALYTICAL COUNTERCURRENT CHROMATOGRAPHS - HIGH-SPEED COUNTERCURRENT CHROMATOGRAPH-4000 VS ANALYTICAL TOROIDAL COIL CENTRIFUGE [J].
OKA, H ;
IKAI, Y ;
KAWAMURA, N ;
YAMADA, M ;
HARADA, KI ;
SUZUKI, M ;
CHOU, FE ;
LEE, YW ;
ITO, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (12) :2309-2328