Computer-aided classification of BI-RADS category 3 breast lesions

被引:18
作者
Buchbinder, SS
Leichter, IS
Lederman, RB
Novak, B
Bamberger, PN
Sklair-Levy, M
Yarmish, G
Fields, SI
机构
[1] Albert Einstein Coll Med, Montefiore Med Ctr, Dept Radiol, Bronx, NY 10467 USA
[2] Jerusalem Coll Technol, Sch Engn, Jerusalem, Israel
[3] Hadassah Univ Hosp, Dept Radiol, IL-91120 Jerusalem, Israel
关键词
breast neoplasms; diagnosis; computers; diagnostic aid;
D O I
10.1148/radiol.2303030089
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate a system for computer-aided classification (CAC) of lesions assigned to Breast Imaging Reporting and Data System (BI-RADS) category 3 at conventional rnammographic interpretation. MATERIALS AND METHODS: A CAC system was used to analyze 106 cases of lesions (42 malignant) that at blinded retrospective interpretation were assigned to BI-RADS category 3 by at least two of four radiologists. The CAC system automatically extracted from the digitized mammograms quantitative features that characterized the lesions. The system then used a classification scheme to score the lesions by the likelihood of their malignancy on the basis of these features. The classification scheme was trained with 646 pathologically proved cases (323 malignant), and the results were tested with receiver operating characteristic (ROC) analysis by using the jackknife method. Sensitivity, specificity, positive predictive value, and accuracy were calculated. Category 3 lesions were stratified among BI-RADS categories 2-5 according to CAC-assigned lesion score and this classification was compared with, the results of pathologic analysis. RESULTS: Jackknife analysis of CAC results in the training data set yielded a sensitivity of 94%, specificity of 78%, positive predictive value of 81%, and area under the ROC curve of 0.90. Of the 42 malignant lesions that had been classified at conventional interpretation as probably benign, nine were assigned by the CAC system to BI-RADS category 4, and 29 were assigned to category 5. The CAC system correctly upgraded the BI-RADS classification of these 38 lesions (sensitivity, 90%) and incorrectly upgraded the classification of only 20 benign lesions (specificity, 69%). CONCLUSION: The CAC system scored 38 of the 42 malignant lesions initially assigned to BI-RADS category 3 as BI-RADS category 4 or 5, and thus correctly upgraded the category in 90% of these lesions. (C) RSNA 2004.
引用
收藏
页码:820 / 823
页数:4
相关论文
共 20 条
[1]  
American College of Radiology, 1999, MAMM QUAL CONTR MAN
[2]  
[Anonymous], BREAST IM REP DAT SY
[3]   Coding mammograms using the classification "probably benign finding - Short interval follow-up suggested" [J].
Caplan, LS ;
Blackman, D ;
Nadel, M ;
Monticciolo, DL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (02) :339-342
[4]   ISOLATED CLUSTERED MICROCALCIFICATIONS - DIAGNOSTIC-VALUE OF MAMMOGRAPHY - SERIES OF 400 CASES WITH SURGICAL VERIFICATION [J].
DELAFONTAN, B ;
DAURES, JP ;
SALICRU, B ;
EYNIUS, F ;
MIHURA, J ;
ROUANET, P ;
LAMARQUE, JL ;
NAJA, A ;
PUJOL, H .
RADIOLOGY, 1994, 190 (02) :479-483
[5]  
Efron B., 1982, SOC IND APPL MATH CB, V38, DOI [10.1137/1.9781611970319, DOI 10.1137/1.9781611970319]
[6]  
Fields S, 1996, INT CONGR SER, V1119, P81
[7]   ANALYSIS OF SPICULATION IN THE COMPUTERIZED CLASSIFICATION OF MAMMOGRAPHIC MASSES [J].
HUO, ZM ;
GIGER, ML ;
VYBORNY, CJ ;
BICK, U ;
LU, P ;
WOLVERTON, DE ;
SCHMIDT, RA .
MEDICAL PHYSICS, 1995, 22 (10) :1569-1579
[8]   Automated computerized classification of malignant and benign masses on digitized mammograms [J].
Huo, ZM ;
Giger, ML ;
Vyborny, CJ ;
Wolverton, DE ;
Schmidt, RA ;
Doi, K .
ACADEMIC RADIOLOGY, 1998, 5 (03) :155-168
[9]  
KENDALL MG, 1968, ADV THEORY STAT, V3, P314
[10]   NEEDLE CORE BIOPSY GUIDED WITH MAMMOGRAPHY - A STUDY OF COST-EFFECTIVENESS [J].
LINDFORS, KK ;
ROSENQUIST, CJ .
RADIOLOGY, 1994, 190 (01) :217-222