Effect of membrane permselectivity on the fouling of cationic membranes during skim milk electroacidification

被引:40
作者
Bazinet, L
Ippersiel, D
Montpetit, D
Mahdavi, B
Amiot, J
Lamarche, F
机构
[1] Agr & Agri Food Canada, Ctr Food Res & Dev, St Hyacinthe, PQ J2S 8E3, Canada
[2] Univ Laval, Ctr Rech Sci & Technol Lait, Ste Foy, PQ G1K 7P4, Canada
[3] Hydro Quebec, Lab Technol Electrochim & Electrotechnol, Shawinigan, PQ G9N 7N5, Canada
关键词
electrochemical; acidification; casein; milk; cationic membrane permselectivity; fouling;
D O I
10.1016/S0376-7388(00)00379-3
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A previous study on skim milk demonstrated that bipolar-membrane electroacidification (BMEA) is a technology that can be used to produce isoelectric precipitation of casein from milk. However, a deposit, suspected to be calcium hydroxide, was observed on the cation-exchange membrane (CEM) side in contact with the base, Also, the performance of the process decreased as well as the lifetime of the membrane. The aim of the present study was therefore to evaluate two types of CEM with different permselectivities in terms of electrodialysis efficiency and membrane parameters, BMEA allowed the separation of high purity bovine mill, casein (about 97% protein), and the permselectivity of both membranes tested does not influence the purity of the isolates produced. However, the migration of cations through the cationic membrane was found to be influenced by the permselectivity leading to isolates with different ash contents. The CSV(TM) membrane slowed down the migration of cations in comparison with CMX(TM) membranes. The membrane fouling of cation-exchange membrane was identified as precipitating calcium and magnesium hydroxides. Moreover, the fouling formed at the outer layer surface of the CEM was demonstrated to be reversible for both membranes while the fouling of the CSV(TM) membrane inner layer was irreversible. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:97 / 110
页数:14
相关论文
共 39 条
[21]  
HARGROVE RE, 1974, FUNDAMENTALS DAIRY C, P58
[22]  
JAUBERT A, 1992, LAIT, V72, P235
[23]   AQUATECH MEMBRANE TECHNOLOGY FOR RECOVERY OF ACID-BASE VALUES FROM SALT STREAMS [J].
MANI, KN ;
CHLANDA, FP ;
BYSZEWSKI, CH .
DESALINATION, 1988, 68 (2-3) :149-166
[24]   ELECTRODIALYSIS WATER SPLITTING TECHNOLOGY [J].
MANI, KN .
JOURNAL OF MEMBRANE SCIENCE, 1991, 58 (02) :117-138
[25]   ION-EXCHANGE MEMBRANES WITH PREFERENTIAL PERMSELECTIVITY FOR MONOVALENT IONS [J].
MIZUTANI, Y .
JOURNAL OF MEMBRANE SCIENCE, 1990, 54 (03) :233-257
[26]   EFFECTS OF LOW CONCENTRATION LEVELS OF CALCIUM AND MAGNESIUM IN THE FEED BRINE ON THE PERFORMANCE OF A MEMBRANE CHLORALKALI CELL [J].
MOMOSE, T ;
HIGUCHI, N ;
ARIMOTO, O ;
YAMAGUCHI, K ;
WALTON, CW .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1991, 138 (03) :735-741
[27]   USE OF BIPOLAR MEMBRANES FOR GENERATION OF ACID AND BASE - ENGINEERING AND ECONOMIC-ANALYSIS [J].
NAGASUBRAMANIAN, K ;
CHLANDA, FP ;
LIU, KJ .
JOURNAL OF MEMBRANE SCIENCE, 1977, 2 (02) :109-124
[28]   EFFECTS OF THE BRINE IMPURITIES ON THE PERFORMANCE OF THE MEMBRANE-TYPE CHLOR-ALKALI CELL [J].
OGATA, Y ;
KOJIMA, T ;
UCHIYAMA, S ;
YASUDA, M ;
HINE, F .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (01) :91-95
[29]  
Pearson A.M., 1983, DEV FOOD PROTEINS, V2