Microchip capillary electrophoresis coupled with a boron-doped diamond electrode-based electrochemical detector

被引:96
作者
Wang, J [1 ]
Chen, G
Chatrathi, MP
Fujishima, A
Tryk, DA
Shin, D
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
[2] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
关键词
D O I
10.1021/ac0262053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The attractive behavior and advantages of a diamond electrode detector for a micromachined capillary electrophoresis (CE) system are discussed. A chemically vapor-deposited boron-doped diamond (BDD) film band (0.3 x 6.0 mm) electrode is used for end-column amperometric detection. The favorable performance of the diamond electrode microchip detector is indicated from comparison to a commonly used thick-film carbon detector. The diamond electrode offers enhanced sensitivity, lower noise levels, and sharper peaks for several groups of important analytes (nitroaromatic explosives, organophosphate nerve agents, phenols). The favorable signal-to-background characteristics of the BDD-based CE detector are coupled with a greatly improved resistance to surface fouling and greater isolation from high separation voltages. The enhanced stability is indicated from a RSD of 0.8% for 60 repetitive measurements of 5 ppm 2,4,6-trinitrotoluene (vs RSD of 10.8% at the thick-film carbon electrode). A highly linear response is obtained for the explosives 1,3-dinitrobenzene and 2,4-dinitrotoluene over the 200-1400 ppb range, with detection limits of 70 and 110 ppb, respectively. Factors influencing the performance of the BDD detector are assessed and optimized. The attractive properties of BDD make it very promising material for electrochemical detection in CE microchip systems and other micromachined flow analyzers.
引用
收藏
页码:935 / 939
页数:5
相关论文
共 25 条
[1]   Lab-on-a-chip: A revolution in biological and medical sciences. [J].
Figeys, D ;
Pinto, D .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :330A-335A
[2]   Current developments in electrophoretic and chromatographic separation methods on microfabricated devices [J].
Kutter, JP .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (06) :352-363
[3]  
Lacher NA, 2001, ELECTROPHORESIS, V22, P2526, DOI 10.1002/1522-2683(200107)22:12<2526::AID-ELPS2526>3.0.CO
[4]  
2-K
[5]   Direct cytochrome c electrochemistry at boron-doped diamond electrodes [J].
Marken, F ;
Paddon, CA ;
Asogan, D .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (01) :62-66
[6]   Carbon paste-based electrochemical detectors for microchip capillary electrophoresis/electrochemistry [J].
Martin, RS ;
Gawron, AJ ;
Fogarty, BA ;
Regan, FB ;
Dempsey, E ;
Lunte, SM .
ANALYST, 2001, 126 (03) :277-280
[7]   Electrochemical glucose detection using nickel-implanted boron-doped diamond electrodes [J].
Ohnishi, K ;
Einaga, Y ;
Notsu, H ;
Terashima, C ;
Rao, TN ;
Park, SG ;
Fujishima, A .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 2002, 5 (03) :D1-D3
[8]   Electrochemical analysis of nucleic acids at boron-doped diamond electrodes [J].
Prado, C ;
Flechsig, GU ;
Gründler, P ;
Foord, JS ;
Marken, F ;
Compton, RG .
ANALYST, 2002, 127 (03) :329-332
[9]  
Prado C, 2002, ELECTROANAL, V14, P262, DOI 10.1002/1521-4109(200202)14:4<262::AID-ELAN262>3.0.CO
[10]  
2-D