Electrochemical glucose detection using nickel-implanted boron-doped diamond electrodes

被引:54
作者
Ohnishi, K
Einaga, Y
Notsu, H
Terashima, C
Rao, TN
Park, SG
Fujishima, A
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[2] Keio Univ, Fac Sci & Technol, Dept Chem, Kanagawa 2238522, Japan
[3] Chungbuk Natl Univ, Dept Ind Chem Engn, Cheongju 361763, Chungbuk, South Korea
关键词
D O I
10.1149/1.1449305
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Nickel-implanted boron-doped diamond electrodes (Ni-DIA) were fabricated in view of their application for carbohydrate detection. This electrode produced well-defined and reproducible voltammograms for 1 mM glucose in alkaline media. The electrode exhibited excellent electrochemical stability with low background current even after ultrasonic treatment, indicating the strong bonding of nickel with carbon. These results indicate the promising use of Ni-DIA for the detection of carbohydrates and amino acids, and thus, an application of ion implantation as the surface modification method is effective for controlling the electrochemical properties of polycrystalline diamond thin films. (C) 2002 The Electrochemical Society.
引用
收藏
页码:D1 / D3
页数:3
相关论文
共 18 条
[1]   CYCLIC VOLTAMMETRIC STUDIES OF CHARGE-TRANSFER REACTIONS AT HIGHLY BORON-DOPED POLYCRYSTALLINE DIAMOND THIN-FILM ELECTRODES [J].
ALEHASHEM, S ;
CHAMBERS, F ;
STROJEK, JW ;
SWAIN, GM ;
RAMESHAM, R .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2812-2821
[2]  
Buchberger W, 1996, FRESEN J ANAL CHEM, V354, P797
[3]   STUDY OF A NICKEL-CATALYZED GLASSY-CARBON ELECTRODE FOR DETECTION OF CARBOHYDRATES IN LIQUID-CHROMATOGRAPHY AND FLOW-INJECTION ANALYSIS [J].
CASELLA, IG ;
DEIMONI, F ;
CATALDI, TRI .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :117-125
[4]  
EINAGA Y, UNPUB
[5]  
FLEISCHMANN M, 1971, J ELECTROANAL CHEM, V31, P39, DOI 10.1016/0368-1874(71)80005-9
[6]   NICKEL-TITANIUM ALLOY ELECTRODE AS A SENSITIVE AND STABLE LC-EC DETECTOR FOR CARBOHYDRATES [J].
LUO, PFF ;
KUWANA, T .
ANALYTICAL CHEMISTRY, 1994, 66 (17) :2775-2782
[7]  
MILLER B, 1994, J ELECTROCHEM SOC, V141, pL41, DOI 10.1149/1.2054873
[8]   Selective electrochemical detection of dopamine in the presence of ascorbic acid at anodized diamond thin film electrodes [J].
Popa, E ;
Notsu, H ;
Miwa, T ;
Tryk, DA ;
Fujishima, A .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 1999, 2 (01) :49-51
[9]   Selective voltammetric and amperometric detection of uric acid with oxidized diamond film electrodes [J].
Popa, E ;
Kubota, Y ;
Tryk, DA ;
Fujishima, A .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1724-1727
[10]   n-type semiconducting diamond by means of oxygen-ion implantation [J].
Prins, JF .
PHYSICAL REVIEW B, 2000, 61 (11) :7191-7194