Selective voltammetric and amperometric detection of uric acid with oxidized diamond film electrodes

被引:196
作者
Popa, E
Kubota, Y
Tryk, DA
Fujishima, A
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[2] Yokohama City Univ, Sch Med, Dept Urol, Kanazawa Ku, Yokohama, Kanagawa 236, Japan
关键词
D O I
10.1021/ac990862m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemically anodized diamond film electrodes were used for selective detection of uric acid (UA) in the presence of high concentrations of ascorbic acid (AA) by differential pulse voltammetry and chronoamperometry. Because the oxidation peak potential for AA is similar to 450 mV more positive than that for UA at anodized diamond electrodes, UA can be determined with very good selectivity. By use of chronoamperometry, linear calibration curves were obtained for UA over the concentration range up to 1 x 10(-6) M in 0.1 M HClO4 solution, with the lowest experimental value measured being 5 x 10(-8) M. This is consistent with the fact that a statistical analysis of the calibration curve yielded a detection limit of 1.5 x 10-8 M (S/N = 3). AA in less than 20-fold excess does not interfere. The practical analytical utility of the method is demonstrated by the measurement of UA in human urine and serum without any preliminary treatment.
引用
收藏
页码:1724 / 1727
页数:4
相关论文
共 28 条
[1]   AN IMPROVED VOLTAMMETRIC METHOD FOR THE DETERMINATION OF TRACE AMOUNTS OF URIC-ACID WITH ELECTROCHEMICALLY PRETREATED CARBON-PASTE ELECTRODES [J].
CAI, XH ;
KALCHER, K ;
NEUHOLD, C ;
OGOREVC, B .
TALANTA, 1994, 41 (03) :407-413
[2]   Morphological and microstructural stability of boron-doped diamond thin film electrodes in an acidic chloride medium at high anodic current densities [J].
Chen, QY ;
Granger, MC ;
Lister, TE ;
Swain, GM .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (11) :3806-3812
[3]   Electroanalysis of dopamine and NADH at conductive diamond electrodes [J].
Fujishima, A ;
Rao, TN ;
Popa, E ;
Sarada, BV ;
Yagi, I ;
Tryk, DA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 473 (1-2) :179-185
[4]   Determination of ascorbic acid in a mixture of ascorbic acid and uric acid at a chemically modified electrode [J].
Gao, ZQ ;
Siow, KS ;
Ng, A ;
Zhang, YM .
ANALYTICA CHIMICA ACTA, 1997, 343 (1-2) :49-57
[5]   VOLTAMMETRIC AND AMPEROMETRIC BEHAVIOR OF URIC-ACID AT BARE AND SURFACE-MODIFIED SCREEN-PRINTED ELECTRODES - STUDIES TOWARDS A DISPOSABLE URIC-ACID SENSOR [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1992, 117 (08) :1299-1303
[6]   Electrochemistry at boron-doped diamond films grown on graphite substrates: redox-, adsorption and deposition processes [J].
Goeting, CH ;
Jones, F ;
Foord, JS ;
Eklund, JC ;
Marken, F ;
Compton, RG ;
Chalker, PR ;
Johnston, C .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 442 (1-2) :207-216
[7]   Flow injection analysis with diamond thin-film detectors [J].
Jolley, S ;
Koppang, M ;
Jackson, T ;
Swain, GM .
ANALYTICAL CHEMISTRY, 1997, 69 (20) :4099-4107
[8]   THEORETICAL-STUDY OF A 1E, 1H+ SURFACE ELECTROCHEMICAL REACTION (4-MEMBER SQUARE SCHEME) WHEN THE PROTONATION REACTIONS ARE AT EQUILIBRIUM [J].
LAVIRON, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 109 (1-3) :57-67
[9]   Hydrogen and oxygen evolution on boron-doped diamond electrodes [J].
Martin, HB ;
Argoitia, A ;
Landau, U ;
Anderson, AB ;
Angus, JC .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (06) :L133-L136
[10]   Uricase-catalyzed oxidation of uric acid using an artificial electron acceptor and fabrication of amperometric uric acid sensors with use of a redox ladder polymer [J].
Nakaminami, T ;
Ito, S ;
Kuwabata, S ;
Yoneyama, H .
ANALYTICAL CHEMISTRY, 1999, 71 (10) :1928-1934