Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: evaluation of Beckman Coulter flow-count fluorospheres and the tetraONE system

被引:80
作者
Reimann, KA
O'Gorman, MRG
Spritzler, J
Wilkening, CL
Sabath, DE
Helm, K
Campbell, DE
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess med Ctr, Div Viral Pathogenesis, Boston, MA 02215 USA
[2] Harvard Univ, Sch Publ Hlth, Boston, MA 02115 USA
[3] Northwestern Univ, Childrens Mem Hosp, Chicago, IL 60614 USA
[4] Univ Washington, Seattle, WA 98195 USA
[5] Univ Colorado, Hlth Sci Ctr, Denver, CO USA
[6] Childrens Hosp Philadelphia, Philadelphia, PA 19104 USA
[7] Univ Calif San Diego, San Diego, CA 92103 USA
[8] Univ Calif Los Angeles, Los Angeles, CA USA
[9] Hlth Canada, Bur HIV AIDS & STD, Ottawa, ON K1A 0L2, Canada
[10] Ctr Dis Control & Prevent, Atlanta, GA USA
[11] Univ N Carolina, Chapel Hill, NC USA
[12] Indiana Univ, Indianapolis, IN 46204 USA
[13] NIAID, DAIDA, NIH, Bethesda, MD 20892 USA
关键词
D O I
10.1128/CDLI.7.3.344-351.2000
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
New analytic methods that permit absolute CD4 and CD8 T-cell determinations to be performed entirely on the flow cytometer have the potential for improving assay precision and accuracy, In a multisite trial, we compared two different single-platform assay methods with a predicate two color assay in which the absolute lymphocyte count was derived by conventional hematology, A two-color method employing lymphocyte light scatter gating and Beckman Coulter Flow-Count fluorospheres for absolute counting produced within-laboratory precision equivalent to that of the two-color predicate method, as measured by coefficient of variation of replicate measurements. The fully automated Beckman Coulter tetraONE System four-color assay employing CD45 lymphocyte gating, automated analysis, and absolute counting by fluorospheres resulted in a small but significant improvement in the within-laboratory precision of CD4 and CD8 cell counts and percentages suggesting that the CD45 lymphocyte gating and automated analysis might have contributed to the improved performance. Both the two-color method employing Flow-Count fluorospheres and the four-color tetraONE System provided significant and substantial improvements in between-laboratory precision of absolute counts, In some laboratories, absolute counts obtained by the single-platform methods showed small but consistent differences relative to the predicate method. Comparison of each laboratory's absolute counts with the five laboratory median value suggested that these differences resulted from a bias in the absolute lymphocyte count obtained from the hematology instrument in some laboratories. These results demonstrate the potential for single-platform assay methods to improve within-laboratory and between-laboratory precision of CD4 and CDS T-cell determinations compared with conventional assay methods.
引用
收藏
页码:344 / 351
页数:8
相关论文
共 19 条
[1]   CONSISTENCY OF ROUTINE MEASUREMENTS OF CD4+, CD8+ PERIPHERAL-BLOOD LYMPHOCYTES [J].
ABOULKER, JP ;
AUTRAN, B ;
BELDJORD, K ;
TOURAINE, F ;
DEBRE, P .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 154 (02) :155-161
[2]   GUIDELINE FOR FLOW CYTOMETRIC IMMUNOPHENOTYPING - A REPORT FROM THE NATIONAL-INSTITUTE-OF-ALLERGY-AND-INFECTIOUS-DISEASES, DIVISION OF AIDS [J].
CALVELLI, T ;
DENNY, TN ;
PAXTON, H ;
GELMAN, R ;
KAGAN, J .
CYTOMETRY, 1993, 14 (07) :702-715
[3]  
*CDCP, 1997, MMWR-MORBID MORTAL W, V46, P1
[4]   STANDARDIZATION OF ABSOLUTE CD4(+) LYMPHOCYTE COUNTS ACROSS LABORATORIES - AN EVALUATION OF THE ORTHO CYTORONABSOLUTE FLOW-CYTOMETRY SYSTEM ON NORMAL DONORS [J].
CONNELLY, MC ;
KNIGHT, M ;
GIORGI, JV ;
KAGAN, J ;
LANDAY, AL ;
PARKER, JW ;
PAGE, E ;
SPINO, C ;
WILKENING, C ;
MERCOLINO, TJ .
CYTOMETRY, 1995, 22 (03) :200-210
[5]   QUALITY-CONTROL IN THE FLOW CYTOMETRIC MEASUREMENT OF LYMPHOCYTE-T SUBSETS - THE MULTICENTER AIDS COHORT STUDY EXPERIENCE [J].
GIORGI, JV ;
CHENG, HL ;
MARGOLICK, JB ;
BAUER, KD ;
FERBAS, J ;
WAXDAL, M ;
SCHMID, I ;
HULTIN, LE ;
JACKSON, AL ;
PARK, L ;
TAYLOR, JMG .
CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1990, 55 (02) :173-186
[6]   CHARACTERIZATION OF T-LYMPHOCYTE SUBSET ALTERATIONS BY FLOW-CYTOMETRY IN HIV DISEASE [J].
GIORGI, JV .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1993, 677 :126-137
[7]  
HO HN, 1993, J IMMUNOL, V150, P3070
[8]   EVALUATION OF 4 ALTERNATIVE METHODOLOGIES FOR DETERMINATION OF ABSOLUTE CD4(+) LYMPHOCYTE COUNTS [J].
JOHNSON, D ;
HIRSCHKORN, D ;
BUSCH, MP .
JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES AND HUMAN RETROVIROLOGY, 1995, 10 (05) :522-530
[9]   An approach to the validation of markers for use in AIDS clinical trials [J].
Mildvan, D ;
Landay, A ;
DeGruttola, V ;
Machado, SG ;
Kagan, J .
CLINICAL INFECTIOUS DISEASES, 1997, 24 (05) :764-774
[10]   EVALUATION OF ALTERNATIVE CD4 TECHNOLOGIES FOR THE ENUMERATION OF CD4 LYMPHOCYTES [J].
NICHOLSON, JKA ;
VELLECA, WM ;
JUBERT, S ;
GREEN, TA ;
BRYAN, L .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 177 (1-2) :43-54