Convergence and Parameter Choice for Monte-Carlo Simulations of Diffusion MRI

被引:162
作者
Hall, Matt G. [1 ]
Alexander, Daniel C. [1 ]
机构
[1] UCL, CMIC, London WC1E 6BT, England
基金
英国工程与自然科学研究理事会;
关键词
Data synthesis; diffusion magnetic resonance imaging (MRI); diffusion tensor imaging; Monte-Carlo simulation; validation; RESTRICTED DIFFUSION; SPIN-ECHO; SELF-DIFFUSION; WHITE-MATTER; MAGNETIC-RESONANCE; WATER DIFFUSION; OPTIC-NERVE; HUMAN BRAIN; MODEL; CORD;
D O I
10.1109/TMI.2009.2015756
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper describes a general and flexible Monte-Carlo simulation framework for diffusing spins that generates realistic synthetic data for diffusion magnetic resonance imaging. Similar systems in the literature consider only simple substrates and their authors do not consider convergence and parameter optimization. We show how to run Monte-Carlo simulations within complex irregular substrates. We compare the results of the Monte-Carlo simulation to an analytical model of restricted diffusion to assess precision and accuracy of the generated results. We obtain an optimal combination of spins and updates for a given run time by trading off number of updates in favor of number of spins such that precision and accuracy of sythesized data are both optimized. Further experiments demonstrate the system using a tissue environment that current analytic models cannot capture. This tissue model incorporates swelling, abutting, and deformation. Swelling-induced restriction in the extracellular space due to the effects of abutting cylinders leads to large departures from the predictions of the analytical model, which does not capture these effects. This swelling-induced restriction may be an important mechanism in explaining the changes in apparent diffusion constant observed in the aftermath of acute ischemic stroke.
引用
收藏
页码:1354 / 1364
页数:11
相关论文
共 43 条
[1]   FIBER COMPOSITION OF THE HUMAN CORPUS-CALLOSUM [J].
ABOITIZ, F ;
SCHEIBEL, AB ;
FISHER, RS ;
ZAIDEL, E .
BRAIN RESEARCH, 1992, 598 (1-2) :143-153
[2]   A general framework for experiment design in diffusion MRI and its application in measuring direct tissue-microstructure features [J].
Alexander, Daniel C. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) :439-448
[3]   Optimal imaging parameters for fiber-orientation estimation in diffusion MRI [J].
Alexander, DC ;
Barker, GJ .
NEUROIMAGE, 2005, 27 (02) :357-367
[4]   Multiple-fiber reconstruction algorithms for diffusion MRI [J].
Alexander, DC .
WHITE MATTER IN COGNITIVE NEUROSCIENCE: ADVANCES IN DIFFUSION TENSOR IMAGING AND ITS APPLICATIONS, 2005, 1064 :113-+
[5]   Effects of osmotically driven cell volume changes on diffusion-weighted imaging of the rat optic nerve [J].
Anderson, AW ;
Zhong, JH ;
Petroff, OAC ;
Szafer, A ;
Ransom, BR ;
Prichard, JW ;
Gore, JC .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) :162-167
[6]  
[Anonymous], 1997, Foundations of Modern probability Theory
[7]  
Assaf Y., 2005, NEUROIMAGE, V30, P1100
[8]   THE NMR SELF-DIFFUSION METHOD APPLIED TO RESTRICTED DIFFUSION - SIMULATION OF ECHO ATTENUATION FROM MOLECULES IN SPHERES AND BETWEEN PLANES [J].
BALINOV, B ;
JONSSON, B ;
LINSE, P ;
SODERMAN, O .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 104 (01) :17-25
[9]  
ben-Avraham D., 2000, DIFFUSION REACTIONS
[10]   PULSED-GRADIENT SPIN-ECHO NMR FOR PLANAR, CYLINDRICAL, AND SPHERICAL PORES UNDER CONDITIONS OF WALL RELAXATION [J].
CALLAGHAN, PT .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1995, 113 (01) :53-59