Experimental measurement of the dynamic photothermal effect in Fabry-Perot cavities for gravitational wave detectors

被引:38
作者
De Rosa, M
Conti, L
Cerdonio, M
Pinard, M
Marin, F
机构
[1] Univ Florence, Dipartimento Fis, Ist Nazl Fis Nucl, Sez Firenze, I-50019 Sesto Fiorentino, FI, Italy
[2] LENS, I-50019 Sesto Fiorentino, FI, Italy
[3] Univ Padua, Dipartimento Fis, I-35131 Padua, Italy
[4] Ist Nazl Fis Nucl, Sez Padova, I-35131 Padua, Italy
[5] Lab Kastler Brossel, F-75252 Paris, France
关键词
D O I
10.1103/PhysRevLett.89.237402
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We report the experimental observation of the frequency dependence of the photothermal effect. The measurements are performed by modulating the laser power absorbed by the mirrors of two high-finesse Fabry-Perot cavities. The results are very well described by a recently proposed theoretical model [M. Cerdonio, L. Conti, A. Heidmann, and M. Pinard, Phys. Rev. D 63, 082003 (2001)], confirming the correctness of such calculations. Our observations and quantitative characterization of the dynamic photothermal effect demonstrate its critical importance for interferometric displacement measurements towards the quantum limit, as those necessary for gravitational wave detection.
引用
收藏
页数:4
相关论文
共 16 条
[1]   Optical bistability induced by mirror absorption: measurement of absorption coefficients at the sub-ppm level [J].
An, K ;
Sones, BA ;
FangYen, C ;
Dasari, RR ;
Feld, MS .
OPTICS LETTERS, 1997, 22 (18) :1433-1435
[2]  
BENSON S, 2000, P 22 INT FREE EL LAS
[3]   Thermodynamical fluctuations and photo-thermal shot noise in gravitational wave antennae [J].
Braginsky, VB ;
Gorodetsky, ML ;
Vyatchanin, SP .
PHYSICS LETTERS A, 1999, 264 (01) :1-10
[4]   Wideband dual sphere detector of gravitational waves [J].
Cerdonio, M ;
Conti, L ;
Lobo, JA ;
Ortolan, A ;
Taffarello, L ;
Zendri, JP .
PHYSICAL REVIEW LETTERS, 2001, 87 (03) :31101-1
[5]   Thermoelastic effects at low temperatures and quantum limits in displacement measurements [J].
Cerdonio, M ;
Conti, L ;
Heidmann, A ;
Pinard, M .
PHYSICAL REVIEW D, 2001, 63 (08)
[6]   Optical transduction chain for gravitational wave bar detectors [J].
Conti, L ;
Cerdonio, M ;
Taffarello, L ;
Zendri, JP ;
Ortolan, A ;
Rizzo, C ;
Ruoso, G ;
Prodi, GA ;
Vitale, S ;
Cantatore, G ;
Zavattini, E .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02) :554-558
[7]   Low-amplitude-noise laser for AURIGA detector optical readout [J].
Conti, L ;
De Rosa, M ;
Marin, F .
APPLIED OPTICS, 2000, 39 (31) :5732-5738
[8]  
CONTI L, GRQC0205115
[9]  
De Rosa M, 2002, CLASSICAL QUANT GRAV, V19, P1919, DOI 10.1088/0264-9381/19/7/393
[10]   Stability of giant Fabry-Perot cavities of interferometric gravitational-wave detectors [J].
Dhurandhar, SV ;
Hello, P ;
Sathyaprakash, BS ;
Vinet, JY .
APPLIED OPTICS, 1997, 36 (22) :5325-5334